Design and characterization of AmLi neutron sources for the LZ experiment

Abstract: In this paper we describe the development, testing, and characterization of three lowemission rate AmLi neutron sources. The sources are used to calibrate the nuclear recoil response of the LUX-ZEPLIN (LZ) dark matter experiment. The sources' neutron emission rate was measured using 3 He proportional tubes. The sources' gamma emissions were characterized using a HPGe detector. Source validated G 4 Monte Carlo simulations allowed to calibrate the Ge and neutron detector responses.