Design and construction of a hydro-pneumatic mock circulation loop that emulates the systemic circuit of the circulatory system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…Mock circulatory systems can be also used to test stents, anastomoses, vascular grafts, prosthetic heart valves and artificial blood vessels, as well as to assess models for hemodynamic predictions after vascular access surgery (e.g., for hemodialysis patients). Some systems have been even designed as loads for real pumping hearts [55][56][57][58][59][60][61][62][63][64][65][66][67][68][69][70][71][72]. Finally, there are many studies in which pulse pressure has been investigated from a biomechanical point of view .…”
Section: Fields Of Applications For Arterial Simulatorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Mock circulatory systems can be also used to test stents, anastomoses, vascular grafts, prosthetic heart valves and artificial blood vessels, as well as to assess models for hemodynamic predictions after vascular access surgery (e.g., for hemodialysis patients). Some systems have been even designed as loads for real pumping hearts [55][56][57][58][59][60][61][62][63][64][65][66][67][68][69][70][71][72]. Finally, there are many studies in which pulse pressure has been investigated from a biomechanical point of view .…”
Section: Fields Of Applications For Arterial Simulatorsmentioning
confidence: 99%
“…Despite the system showed acceptable reproducibility and repeatability, data consistency and stability still needed to be assured. Another experimental flow loop mimicking the cardiovascular system circuit was designed by Vilchez-Monge et al [67]: the simulated circuit contained the right side of the heart, simulated arteries and veins. In order to monitor both pressure and flows, the authors inserted an absolute pressure sensor with a response time of 1 ms and accuracy of ±2.5% with respect to the FS voltage, and a flow meter with ±3% accuracy, with a measurement range from 1 to 30 L•min −1 .…”
Section: Legendre and Vilchez-monge's Design Of An Artificial Cardiov...mentioning
confidence: 99%