Design and Evaluation of a Steerable Magnetic Sheath for Cardiac Ablations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 42 publications
(23 citation statements)
references
References 19 publications
1
22
0
Order By: Relevance
“…As the water temperature rose, the device with the full hydrogel dimensions gradually uncurled to straighten the tip, reaching a bending angle of 170° when temperature was raised to 50 °C. This bending amount is found to be the largest among other reported smart-material-based catheters (13-155°) [13][14][15][16]. As also can be seen, the devices with the halved length or thickness of the hydrogel layer showed actuations with reduced bending angles as expected.…”
Section: Characterization Of Pnipam Synthesized On the Flexible Stripsupporting
confidence: 74%
See 1 more Smart Citation
“…As the water temperature rose, the device with the full hydrogel dimensions gradually uncurled to straighten the tip, reaching a bending angle of 170° when temperature was raised to 50 °C. This bending amount is found to be the largest among other reported smart-material-based catheters (13-155°) [13][14][15][16]. As also can be seen, the devices with the halved length or thickness of the hydrogel layer showed actuations with reduced bending angles as expected.…”
Section: Characterization Of Pnipam Synthesized On the Flexible Stripsupporting
confidence: 74%
“…Different approaches to this goal have been reported [13][14][15][16]. One promising approach that has been widely investigated is to use responsive "smart" materials as the actuator element aiming to achieve greater bending controllability, simpler system configurations, and miniaturization of the active tip [17].…”
Section: Introductionmentioning
confidence: 99%
“…Next, the magnetic steering demonstrated in the paper was achieved manually by adjusting the position and orientation of a single permanent magnet. To improve the accuracy and precision, existing magnetic manipulation systems (15,(47)(48)(49)(50) or more recent developments in omnidirectional and/or spatially selective magnetic field control (17,18,21,(51)(52)(53) will need to be adopted for further translation of the proposed concept of ferromagnetic soft continuum robots.…”
Section: Discussionmentioning
confidence: 99%
“…S7). While guidewires/catheters with different single magnets have been fabricated (18)(19)(20)(21)(22)(23), their half workspaces are always a curve with an area of 0 (Fig. 5 and SI Appendix, section 3).…”
Section: [3]mentioning
confidence: 99%
“…Existing MSCRs are mostly fabricated by embedding one or more permanent magnets in the distal portion of the MSCR (18)(19)(20)(21)(22)(23)(24)(25). More recently, a new type of MSCR has been developed by uniformly dispersing hard-magnetic particles in elastomeric fibers (16) (Fig.…”