Design and evaluation of an intelligent reduction robot system for the minimally invasive reduction in pelvic fractures

Abstract: Introduction Pelvic fracture is a severe high-energy injury with the highest disability and mortality of all fractures. Traditional open surgery is associated with extensive soft tissue damages and many complications. Minimally invasive surgery potentially mitigates the risks of open surgical procedures and is becoming a new standard for pelvic fracture treatment. The accurate reduction has been recognized as the cornerstone of minimally invasive surgery for pelvic fracture. At present, the clo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
20
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 22 publications
(20 citation statements)
references
References 50 publications
0
20
0
Order By: Relevance
“…Screw positioning, evaluated by Florian Gras classification, was notably improved in the TiRobot group in our meta-analysis. Reduction is a crucial step in the surgical treatment of bone fractures to achieve anatomical alignment and facilitate healing [ 37 , 38 ]. The Matta score evaluates the reduction quality of pelvic fractures [ 38 ].…”
Section: Discussionmentioning
confidence: 99%
“…Screw positioning, evaluated by Florian Gras classification, was notably improved in the TiRobot group in our meta-analysis. Reduction is a crucial step in the surgical treatment of bone fractures to achieve anatomical alignment and facilitate healing [ 37 , 38 ]. The Matta score evaluates the reduction quality of pelvic fractures [ 38 ].…”
Section: Discussionmentioning
confidence: 99%
“…Step Calculate the orientation difference. Based on the symmetry of the pelvis, 5,27 the target position (datum ilium) for the reduction was generated in the Solidworks from a mirror operation. As shown in Figure 4, a centre‐of‐mass coordinate system C1 aligned with the model coordinate system M is created using the centre‐of‐mass of the datum ilium as the origin.…”
Section: Methodsmentioning
confidence: 99%
“…As a modern technology with high precision, reliability, and intelligence, robotics is widely used in medical, industrial, and aerospace fields. Therefore, the reduction movements during pelvic fracture closed reduction surgery can be performed by controlling the robot 4–6 …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Numerous novel technologies, such as orthopedic surgical robot navigation, computer-aided navigation, and orthopedic minimally invasive intelligent visualization system, have been invented to optimize the process of channel screw placement [3][4][5] . However, including the most widely used freehand method, these technologies cannot satisfy the needs of simplicity, accuracy, and low radiation exposure simultaneously [6] .…”
Section: Introductionmentioning
confidence: 99%