2017 IEEE 58th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON) 2017
DOI: 10.1109/rtucon.2017.8124782
|View full text |Cite
|
Sign up to set email alerts
|

Design and evaluation of control system for static VAR compensators with thyristors switched reactors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 8 publications
0
7
0
1
Order By: Relevance
“…The maximum reactive power is an inverse function of the voltage thus their usefulness decreases when they are needed the most in a power system. The use of the SVC to improve a power system's voltage stability under normal and during system disturbances such as line outages and line faults [10] and for rotor angle stability improvement [11] have been widely studied. The static synchronous compensator (STATCOM) is based on the DC-AC switching converter.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The maximum reactive power is an inverse function of the voltage thus their usefulness decreases when they are needed the most in a power system. The use of the SVC to improve a power system's voltage stability under normal and during system disturbances such as line outages and line faults [10] and for rotor angle stability improvement [11] have been widely studied. The static synchronous compensator (STATCOM) is based on the DC-AC switching converter.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The analysis of publications shows that the shunt-connected reactive power compensators based on the TSC and TCR is developed only for the symmetric compensation of the reactive power and practically is employed just for high and medium voltage lines of the utility grid (Acha, 2002;Čerňan & Tlustý, 2015;Chang & Liao, 2017;Dixon et al, 2005;Farkoush et al, 2016;Fuchs & Masoum, 2011;Hong Hu et al, 2015;Igbinovia et al, 2015;Ilisiu & Dinu, 2019;Liberado et al, 2013;Liu et al, 2016;Mathur & Varma, 2002;Padiyar, 2007;D. I. Panfilov et al, 2017aD.…”
Section: Shunt-connected Reactive Power Compensatormentioning
confidence: 99%
“…Iš literatūros apžvalgos matyti, kad reaktyviosios galios kompensatoriai su šuntu, tik simetriniam reaktyviosios galios kompensavimui ir yra praktiškai taikomi tik aukštos ir vidutinė įtampos tinkluose. (Acha, 2002;Čerňan & Tlustý, 2015;Chang & Liao, 2017;Dixon et al, 2005;Farkoush et al, 2016;Fuchs & Masoum, 2011;Hong Hu et al, 2015;Igbinovia et al, 2015;Ilisiu & Dinu, 2019;Liberado et al, 2013;Liu et al, 2016;Mathur & Varma, 2002;Padiyar, 2007;D. I. Panfilov et al, 2017aD.…”
Section: Ac Ac L V1 V2unclassified
“…The switched-based SVC present a vital solution to remove the harmonics during the control of the reactive power. But, it should be considered that, the switched SVCs have discrete performance during the control of reactive power; consequently, they require different control and design methodology to obtain the smoothest characteristic [12].…”
Section: Introductionmentioning
confidence: 99%