2020
DOI: 10.5829/ije.2020.33.08b.24
|View full text |Cite
|
Sign up to set email alerts
|

Design and Experimental Study of a Combined Pneumatic Plot Seed-metering Device for Cotton

Abstract: This study presents a combined pneumatic seed-metering device (SMD) that could not only fill, carry, and meter seeds, but also switch quickly between seed-metering and seed-cleaning modes, and clean seeds thoroughly and rapidly. The seed-filling, seed-carrying, and seed-metering modes of the SMD were analyzed based on a theoretical kinematic model. Furthermore, a three-factor, three-level orthogonal test was conducted by using a performance test bench arranged for the SMD as well as Design-Expert software. The… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…Authors [21] examined the performance of a pneumatic vacuum seeding system. The test was performed in the laboratory and cotton seedplates with a hole diameter of 3.5 mm and a different number of holes (22,30,36,40,48,60,72) were used. The rotational speed of the seedplates ranged from 0.15-0.85 m/s.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Authors [21] examined the performance of a pneumatic vacuum seeding system. The test was performed in the laboratory and cotton seedplates with a hole diameter of 3.5 mm and a different number of holes (22,30,36,40,48,60,72) were used. The rotational speed of the seedplates ranged from 0.15-0.85 m/s.…”
Section: Introductionmentioning
confidence: 99%
“…The highest values of the QFI index were achieved at a rotational speed of 0.35 m/s in seedplates with 22, 40, 48 and 60 holes. Authors [22] state that a vacuum of 2.67 kPa at rotational speed of seedplate of 20 min −1 with hole diameter of 2.83 mm achieved a MISS Index of 0.59%. They also state that the same rotational speed of the seedplate at reduced vacuum to 2.35 kPa at a hole of 2.78 mm results in relatively low MULT Index values (4.3%).…”
Section: Introductionmentioning
confidence: 99%
“…Singh et al [6] designed a cotton metering device to achieve precision in spacing by optimizing the running speed of the metering tray, vacuum pressure and the entry shape of the suction hole. Liu et al [7] designed a combined cotton metering device. After optimization, the optimal combination that achieved the lowest missed seeding index (0.59%) was as below: a vacuum pressure of 2.67 kPa, a slot width of 2.83 mm, and an angular velocity of 20 r/min.…”
Section: Introductionmentioning
confidence: 99%