2000
DOI: 10.1016/s0924-0136(00)00682-8
|View full text |Cite
|
Sign up to set email alerts
|

Design and manufacture of anatomical hip joint endoprostheses using CAD/CAM systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
36
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(36 citation statements)
references
References 4 publications
0
36
0
Order By: Relevance
“…They are usually used as position references in many applications, such as preoperative planning, virtual surgical operation, intraoperative navigation, patient-specific prosthesis design, etc. Automatically recognizing anatomical landmarks is an urgent task in the digital surgery field [3][4][5][6][7][8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…They are usually used as position references in many applications, such as preoperative planning, virtual surgical operation, intraoperative navigation, patient-specific prosthesis design, etc. Automatically recognizing anatomical landmarks is an urgent task in the digital surgery field [3][4][5][6][7][8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…Thus, a custom-made prosthesis has to be made for the patient. Anatomical features of the human skeletomuscular system are usually taken into account in the designs of custom hip implants [2], this may enhance load transfer from the implant to bone [3][4][5]. Along with numerous CAD (Computer Aided Design) systems offering parametric geometry, parametric-oriented design of a hip implant based on anthropometrics study becomes possible [6].…”
Section: Introductionmentioning
confidence: 99%
“…Along with numerous CAD (Computer Aided Design) systems offering parametric geometry, parametric-oriented design of a hip implant based on anthropometrics study becomes possible [6]. Design of custom hip prosthesis, according to computer tomography (CT) images, has been introduced in many articles [1,2,[6][7][8]. In some cases (such as hip implant repair cases), computer tomography images needed cannot be utilized to reconstruct the femoral cavity of the patient because some high-density matter (such as metal) can cause them to be blurry, which results in a custom hip implant that cannot be designed based on computer tomography images.…”
Section: Introductionmentioning
confidence: 99%
“…Werner et al, 2000, outlined a methodology for the design and manufacture of a custom femur endoprosthesis. Again, in this methodology the CAD data for the specific bone came from a CT scan.…”
Section: Chapter 2 Literature Reviewmentioning
confidence: 99%
“…It could be advantageous for a patient to receive a custom fabricated orthopaedic implant that would better fit into their unique bone structure. An implant that better fits into host bone could create a stronger attachment that could offer more functionality for the patient and reduce the chances of implant loosening (Werner et al, 2000). The option for customizable, patient-specific, orthopaedic implants is not commercially feasible at this time but could be of great benefit to any patient requiring such medical attention.…”
Section: Chapter 1 Introductionmentioning
confidence: 99%