2023
DOI: 10.1016/j.nima.2022.167635
|View full text |Cite
|
Sign up to set email alerts
|

Design and optimization of a Goubau line for calibration of BPMs for particle accelerators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…We considered different pump power levels and wavelengths for RFA, as well as various configurations of hybrid EDFA-RFA. The table (2) and figure (12) show the best values obtained for each configuration. The optical amplifiers' performance was assessed based on gain, NF, Q factor, and BER.…”
Section: The Optical Amplifiermentioning
confidence: 99%
See 2 more Smart Citations
“…We considered different pump power levels and wavelengths for RFA, as well as various configurations of hybrid EDFA-RFA. The table (2) and figure (12) show the best values obtained for each configuration. The optical amplifiers' performance was assessed based on gain, NF, Q factor, and BER.…”
Section: The Optical Amplifiermentioning
confidence: 99%
“…When a Gaussian light beam is directed towards a dielectric interface, it deviates from geometric optics predictions. This deviation, known as non-specular shifts, has been studied by researchers from the early 20th century to the present day [2]. Various practical applications built on these shifts have proven to be highly intriguing [3].…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…To test the machining quality of the HEPS BPMs, a calibration system based on stretched wires was set up in a room with constant temperature and humidity [17]. We fixed the BPM on a movement platform, the electromagnetic field on the stretched wire was used to simulate the beam, and the responding of the BPM to beam was recorded by the calibration system.…”
Section: Comparison Between the Cst Simulation And Calibration System...mentioning
confidence: 99%
“…Conical launchers have often been used to launch Goubau waves [3,19,20]. The conical launcher is a natural choice because of the similarity between the TEM wave mode in a coaxial feed and the TM fields in the Goubau mode.Here we explore the performance of conical launchers by simulation, including both large and small-radius conductors.…”
Section: Conical Goubau Wave Launchermentioning
confidence: 99%