Design and Preliminary Evaluation of a Perturbation-based Robot-assisted Assessment of Hand Sensorimotor Impairments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
2
1
1

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 35 publications
0
5
0
Order By: Relevance
“…The ETH MIKE (Motor Impairment and Kinesthetic Evaluation) 2 is a one degree of freedom end-effector robot, which can provide well-controlled stimuli to the index finger and sensitively measure subjects' kinematic and kinetic responses [41,42]. The end-effector has its center of rotation aligned with the MCP joint of the index finger.…”
Section: Robot-assisted Assessments Apparatusmentioning
confidence: 99%
See 1 more Smart Citation
“…The ETH MIKE (Motor Impairment and Kinesthetic Evaluation) 2 is a one degree of freedom end-effector robot, which can provide well-controlled stimuli to the index finger and sensitively measure subjects' kinematic and kinetic responses [41,42]. The end-effector has its center of rotation aligned with the MCP joint of the index finger.…”
Section: Robot-assisted Assessments Apparatusmentioning
confidence: 99%
“…The objective of this work was to propose and evaluate a new set of assessments of hand proprioceptive, motor and sensorimotor impairments, implemented on a single, previously described robotic platform (ETH MIKE: Motor Impairment and Kinesthetic Evaluation) [41,42]. This one degree-of-freedom end-effector device can provide well-controlled movement stimuli to the index finger metacarpophalangeal (MCP) joint and sensitively measure its kinematic and kinetic responses.…”
Section: Introductionmentioning
confidence: 99%
“…The ETH MIKE is a one-degree-of-freedom end-effector device, that can be used to measure impairment of proprioception, motor and sensorimotor function in the metacarpophalangeal joint of the index finger (23,54,55). The ETH MIKE provides well-controlled stimuli to the index finger and sensitively measures the kinematic and kinetic responses, and has been shown to be safe and feasible in post-stroke individuals with mild to severe disability levels (23).…”
Section: Eth Motor Impairment and Kinesthetic Evaluation (Mike)mentioning
confidence: 99%
“…The ETH MIKE (Motor Impairment and Kinesthetic Evaluation) is a one degree of freedom end-effector robot, which can provide well-controlled stimuli to the index finger and sensitively measure subjects' kinematic and kinetic responses [40,41].…”
Section: Apparatusmentioning
confidence: 99%
“…Motor Impairment and Kinesthetic Evaluation) [40,41]. This one degree-of-freedom end-effector device can provide well-controlled movement stimuli to the index finger metacarpophalangeal (MCP) joint and sensitively measure kinematic and kinetic responses.…”
Section: Introductionmentioning
confidence: 99%