Design and validation of an MR‐conditional robot for transcranial focused ultrasound surgery in infants

Abstract: This paper presents a comprehensive look at the process of designing and validating a new robot from concept to implementation for use in an MR environment. An MR conditional robot has been designed and manufactured to design specifications. The system has demonstrated its feasibility as a platform for MRgFUS interventions for neonatal patients. The success of the system in experimental trials suggests that it is ready to be used for validation of the transcranial intervention in animal studies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
24
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 13 publications
(26 citation statements)
references
References 31 publications
2
24
0
Order By: Relevance
“…MR conditional is a device that has been demonstrated to pose no known hazards in a specified MR environment with specified conditions of use such as field strength. MR conditional devices include the pneumatic stepper motor of Chen et al [21] and the prototype robot for transcranial focused ultrasound surgery of Price et al [22]. MR safe devices include the prostate biopsy robots from Stoianovici et al [9], [10] and Schouten et al [23].…”
Section: Section 2: Related Workmentioning
confidence: 99%
“…MR conditional is a device that has been demonstrated to pose no known hazards in a specified MR environment with specified conditions of use such as field strength. MR conditional devices include the pneumatic stepper motor of Chen et al [21] and the prototype robot for transcranial focused ultrasound surgery of Price et al [22]. MR safe devices include the prostate biopsy robots from Stoianovici et al [9], [10] and Schouten et al [23].…”
Section: Section 2: Related Workmentioning
confidence: 99%
“…The needle tip was commanded to puncture these targets, and the error was estimated by the distance from the centre of each target to the corresponding pierced hole 8 . Similarly, in the framework of evaluating the motion accuracy of a robot intended for transcranial focussed ultrasound (FUS) surgery, the FUS transducer was replaced by a felt‐tipped pen, which was commanded to touch multiple resolution points distributed on three perpendicular planes demonstrating the entire robot's workplace 9 . Each created mark was assigned in resolution circles having radial and angular approximation zones for facilitating targeting error measurement 9 .…”
Section: Introductionmentioning
confidence: 99%
“…Similarly, in the framework of evaluating the motion accuracy of a robot intended for transcranial focussed ultrasound (FUS) surgery, the FUS transducer was replaced by a felt‐tipped pen, which was commanded to touch multiple resolution points distributed on three perpendicular planes demonstrating the entire robot's workplace 9 . Each created mark was assigned in resolution circles having radial and angular approximation zones for facilitating targeting error measurement 9 . Another simplified method involves mounting digital callipers on the motion stages of a robot such that their actual displacement after motion execution can be directly measured by the incremental distance of the calliper 10,11 …”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations