2019
DOI: 10.1109/tpel.2018.2819887
|View full text |Cite
|
Sign up to set email alerts
|

Design Considerations for Current-Regulated Series-Resonant Converters With a Constant Input Current

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 28 publications
1
6
0
Order By: Relevance
“…Meanwhile, the rms load current (I Rr ) is reduced. These observations are consistent with equations ( 12), (15), and (34) and the rms current plot in Fig. 8, as the tank input impedance Z i reduces to a small value at f o .…”
Section: (A)supporting
confidence: 90%
See 1 more Smart Citation
“…Meanwhile, the rms load current (I Rr ) is reduced. These observations are consistent with equations ( 12), (15), and (34) and the rms current plot in Fig. 8, as the tank input impedance Z i reduces to a small value at f o .…”
Section: (A)supporting
confidence: 90%
“…This presents a strong opportunity for an improved high-frequency DEH solution using load resonant converters. Resonant converters have been implemented in various highfrequency applications such as wireless power transfer [10]- [12], LED drivers [13], underwater power distribution [14], [15], etc. due to their soft-switching capability and high efficiency.…”
Section: Introductionmentioning
confidence: 99%
“…To carry out an analysis of current source inverters, the method of the first harmonic analysis (FHA) is usually applied [5][6][7][8][9][10] and in applications related to electrotechnology, where the loads are part of resonant circuits with a sufficiently good quality factor, a satisfactory accuracy is achieved, compared to the exact analysis methods that account for the influence of all harmonics. In this aspect, the existing methodologies for the design of current source inverters based on the analysis of the first harmonic method give very good results and use relatively simple calculation procedures.…”
Section: Introductionmentioning
confidence: 99%
“…A CSRL converter controls the current type characteristic load better than a VSRL converter, but current input equipment is not common. A VSRL converter is used if the current output is constant [22,23]. Generated converters, isolated constructors, and a non-planar circuit can be converted using the duality approach [24][25][26][27][28].…”
Section: Introductionmentioning