Design Methodology and Optimization of a Medium-Frequency Transformer for High-Power DC–DC Applications

Abstract: The medium-frequency power transformer (MFPT) is one of the key elements of an isolated, bi-directional DC-DC converters in applications such as future all-DC offshore wind farms, traction and solid state transformers. This paper describes a design methodology taking into account the loss calculation, isolation requirements and thermal management. Incorporating this design methodology, an optimization process with a wide range of parameter variations is applied on a design example to find the highest power den… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
76
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 125 publications
(76 citation statements)
references
References 19 publications
0
76
0
Order By: Relevance
“…Several examples of computer based design optimization can be found in the literature resulting in next MFT prototypes: litz wire/metglas/25 kW/2 kHz [22], litz wire/nanocrystalline and ferrite/166 kW/20 kHz [23], litz wire/nanocrystalline and ferrite/50 kW/5 kHz [24]. They are mostly based on selection and appropriate application of the earlier mentioned and often quite old models thus limiting the quality of the overall optimization process and its results.…”
Section: Kw 10khz Medium Frequency Transformer Design Optimizatiomentioning
confidence: 99%
“…Several examples of computer based design optimization can be found in the literature resulting in next MFT prototypes: litz wire/metglas/25 kW/2 kHz [22], litz wire/nanocrystalline and ferrite/166 kW/20 kHz [23], litz wire/nanocrystalline and ferrite/50 kW/5 kHz [24]. They are mostly based on selection and appropriate application of the earlier mentioned and often quite old models thus limiting the quality of the overall optimization process and its results.…”
Section: Kw 10khz Medium Frequency Transformer Design Optimizatiomentioning
confidence: 99%
“…The case study is performed based on a 35 kW MFT used in a 10 kV EPT. The maximum working voltage of this EPT is 10 kV, thus, the target insulation voltage for this MFT is 10 kV, and safety factor [7] should be considered when determining the insulation distance. The structure of the core type MFT is shown in Figure 2a.…”
Section: Finite Element Modeling Of Mftmentioning
confidence: 99%
“…Previous works regarding MFT can be found in literatures [6][7][8][9][10][11]. Literature [6] presents an improved thermal model for multi-layer winding consisting of litz-wire and the analytical calculation of maximum electric field strength in the core window area.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…For high power energy conversion application, design methods of single-phase transformers operating at medium or high frequencies are introduced [15][16][17]. More recently, in [18], estimations of core losses with non-sinusoidal excitation in medium/high frequency transformer are introduced.…”
Section: Introductionmentioning
confidence: 99%