2016
DOI: 10.1007/978-3-319-33714-2_34
|View full text |Cite
|
Sign up to set email alerts
|

Design of a 3-UPS-RPU Parallel Robot for Knee Diagnosis and Rehabilitation

Abstract: Nowadays, rehabilitation robots represent a field in which a variety of robotic devices have been proposed. One example of such devices is lower-limb rehabilitation robots. Specifically, the knee joint is one of the joints whose rehabilitation is foreseen as a potential task for a robot device. This paper describes the design of a robot for knee diagnosis and rehabilitation. First, we established the design specification by studying the mobility needed at the robot's end-effector to deal with diagnosis and reh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
4
2
1

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 9 publications
0
7
0
1
Order By: Relevance
“…The 3UPS-1RPS parallel manipulator Araujo-Gómez et al in [23] developed the parallel manipulator that will be optimized in this paper. The manipulator's design considers that a rehagnosis task of the knee requires 2R2T motion to be applied on the foot of a lower limb.…”
Section: 1mentioning
confidence: 99%
See 1 more Smart Citation
“…The 3UPS-1RPS parallel manipulator Araujo-Gómez et al in [23] developed the parallel manipulator that will be optimized in this paper. The manipulator's design considers that a rehagnosis task of the knee requires 2R2T motion to be applied on the foot of a lower limb.…”
Section: 1mentioning
confidence: 99%
“…Due to the need of a robot able to perform 2T2R movements at its end-effector, Araujo-Gómez et al in [23] proposed a 3UPS-1RPU PM for knee rehagnosis (rehabilitation and diagnosis). Note that, U, P, R, and S stand for universal, prismatic, revolute and spherical joints.…”
Section: Introductionmentioning
confidence: 99%
“…La diferencia de la movilidad (2T2R) del modelo 3UPE-RPU con los anteriormente expuestos, resulta en una mejora de la emulación de movimientos realizados en programas de rehabilitación; además su configuración con brazo central proporciona mayor rigidez y capacidad de carga [8].…”
Section: A Robot 3upe-rpuunclassified
“…For example, the rehabilitation mechanism that motivated this study [18] was designed for lower limb rehabilitation. We have noted that when the condition number of the Jacobian matrix related to the human leg is determined, there are points where its value is high, implying that the limb at that point does not present good mobility.…”
Section: Introductionmentioning
confidence: 99%