2010
DOI: 10.1016/j.sna.2010.01.010
|View full text |Cite
|
Sign up to set email alerts
|

Design of a low-cost non-destructive system for punctual measurements of salt levels in food products using impedance spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
44
0
6

Year Published

2012
2012
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 66 publications
(54 citation statements)
references
References 23 publications
2
44
0
6
Order By: Relevance
“…Good results were also obtained for salt content prediction of salted meat based on EIS [57,78,79]. It was also found that minced samples had better prediction accuracies than block samples, which indicated that salt homogeneously distributed within meat favorably impacts prediction accuracy.…”
Section: Water Fat and Salt Contentmentioning
confidence: 78%
See 2 more Smart Citations
“…Good results were also obtained for salt content prediction of salted meat based on EIS [57,78,79]. It was also found that minced samples had better prediction accuracies than block samples, which indicated that salt homogeneously distributed within meat favorably impacts prediction accuracy.…”
Section: Water Fat and Salt Contentmentioning
confidence: 78%
“…The parasitic impedance decreases with frequency increasing; thus it can be ignored when frequency is high in bipolar measurement system [17]. Material and configuration of electrodes have an impact on electric field loaded on the tested biological tissue and are important factors in EIS measurements [57,58].…”
Section: Bipolar Measurement Methodmentioning
confidence: 99%
See 1 more Smart Citation
“…This is because the flow of the current through the dissolution is a function of the applied voltage and the chemical concentration in the dissolution. The measurements have been made with a device developed by the Institute of Molecular Recognition and Technological Development (IDM) called FraPlusMini [22], which is capable of running tests for Potentiometry [23], Amperometry [23,24], Pulse Voltammetry and Cyclic Voltammetry [25], and has been successfully used in food [26][27][28], water analyses [29] and also in the determination of environmental parameters [30]. The system consists of a software application that runs on a PC and electronic equipment.…”
Section: Electrochemical Measurement Using Pulse Voltammetrymentioning
confidence: 99%
“…A raíz de nuestro interés en el diseño del sistema de detección 195,196,197,198,199 hemos desarrollado una lengua electrónica voltamétrica simple que se ha utilizado para caracterizar el tratamiento de las aguas afluentes y efluentes para una planta depuradora de aguas residuales domésticas. El sistema propuesto consiste en una array de electrodos metálicos formado por Au, Pt, Ir, Rh, Ag, Cu, Ni y Co y su uso como electrodos de trabajo en los experimentos de voltametría.…”
Section: Capítulounclassified