2013 Pan American Health Care Exchanges (PAHCE) 2013
DOI: 10.1109/pahce.2013.6568332
|View full text |Cite
|
Sign up to set email alerts
|

Design of a piezoelectric immunosensor for tuberculosis biomarker detection

Abstract: Monoclonal antibodies have been applied in biomedical research for diagnosis of various diseases and for the treatment of increasing prevalence diseases such as tuberculosis. There is a need to develop systems capable of detecting tuberculosis-related biomarkers that can provide a quick diagnosis to begin treatment immediately. Thanks to the advances in research for detection, biosensors technologies are emerging as a good alternative for clinical applications. The aim of this work was to develop a piezoelectr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
3

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 23 publications
0
3
0
3
Order By: Relevance
“…Three steps were followed in this paper such as In Ziehl-Neelsen staining approach after satin image are taken for bacilli for samples and cluster method like K-means is used for extracting tissue and bacilli of tuberculosis and at last features with geometric are considered. This paper experimentally produced result with is more effective and precise to identify the bacilli with tuberculosis in the tissue [5].…”
Section: Literature Surveymentioning
confidence: 99%
“…Three steps were followed in this paper such as In Ziehl-Neelsen staining approach after satin image are taken for bacilli for samples and cluster method like K-means is used for extracting tissue and bacilli of tuberculosis and at last features with geometric are considered. This paper experimentally produced result with is more effective and precise to identify the bacilli with tuberculosis in the tissue [5].…”
Section: Literature Surveymentioning
confidence: 99%
“…Actualmente otro inmunosensor piezoeléctrico para la detección de un biomarcador de TB está siendo desarrollado en Colombia por Jaramillo et al, (2013) empleando un formato directo competitivo. En esta propuesta se inmovilizó antígeno 38kDa recombinante de Mtb sobre la superficie del electrodo de oro de un transductor piezoeléctrico empleando SAMs.…”
Section: Discussionunclassified
“…La estandarización de los parámetros de configuración requeridos, para la caracterización topográfica de superficies de oro biofuncionalizadas con SAM de proteínas mediante AFM, se llevó a cabo realizando estudios de caracterización previa empleando cristales de cuarzo biofuncionalizados con: Albumina de suero bovino (BSA) (Jaramillo et al, 2013), el conjugado del hapteno TCP, BSA-TS1 (Manclús y Montoya, 1996) y CFP de Mtb. En la Tabla 1 se resumen los mejores parámetros de configuración encontrados para un microscopio de fuerza atómica y las características que debe tener la sonda, para la exploración de superficies de oro biofuncionalizadas con antígenos proteicos mediante SAMs.…”
Section: Caracterización Topográfica De Cristales Piezoeléctricos Medunclassified
See 1 more Smart Citation
“…This type of sensors was used for detecting antigens of Mycobacterium tuberculosis (Kumar, 2000;Jaramillo et al, 2013).…”
Section: Biosensors and Immunosensorsmentioning
confidence: 99%