2022
DOI: 10.1007/s40435-022-00963-z
|View full text |Cite
|
Sign up to set email alerts
|

Design of a robust adaptive self-tuning regulator controller on single-phase full-bridge grid-connected inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…The primary concept of this process is based on ants' behaviors motions in the search space, while antlion predicts their next move to hunt them [36]. It should be mentioned that the movements of ants are not fixed; thus, their random behavior can be modeled by Equation (5).…”
Section: Optimizer Algorithm Of Antlionmentioning
confidence: 99%
See 2 more Smart Citations
“…The primary concept of this process is based on ants' behaviors motions in the search space, while antlion predicts their next move to hunt them [36]. It should be mentioned that the movements of ants are not fixed; thus, their random behavior can be modeled by Equation (5).…”
Section: Optimizer Algorithm Of Antlionmentioning
confidence: 99%
“…The primary aim of utilizing power converters is regulating the output voltage and ensuring a robust dynamic performance. The objective of designing a feedback loop control is for the stability insurance of the system and appropriate regulation within a predetermined range of operating conditions [4,5]. On the other hand, this converter's system consisted of a zero in the right half-plane, which provides a challenging condition to design flexible and well-behaved controllers.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…To reduce the THD level, inductive filters (L) or capacitive filters (C) are suggested, including, LC, L, LLCL, and LCL. Papers [3][4][5] reported that the characteristics of LC filters make them appropriate options for stand-alone structures (load connected). However, they also pointed out that under high-frequency switching conditions, this topology exhibits a discontinuous behaviour, and that in real-time use, some fractionality and hitherto observed non-linearity also arise [6].…”
Section: Introductionmentioning
confidence: 99%
“…These challenges are covered in refs. [15][16][17] using a robust identification procedure in the controller that does not require a mathematical model of system using Backbox strategy. Meanwhile, these flexible schemes highly rely on the identification process leading to the lack of reliability along with higher instability risk.…”
Section: Introductionmentioning
confidence: 99%