This paper introduces a new approach to the use of membrane-based amperometric sensors which is expected to improve the ruggedness of these sensors significantly relative to the steady-state method in common use. In this new method, the fixed-voltage source used with the conventional steady-state method is replaced by a pulsed-voltage source. Unlike the fixed-source approach, which yields steady-state currents corresponding to large differences between analyte concentrations inside and outside the isolating membrane, the pulsed-source approach permits measurement of currents corresponding to near-equilibrium conditions between solutions inside and outside the membrane. Because the measured currents correspond to near-equilibrium conditions, results are expected to be virtually independent of variables that affect rates of mass transport to and across the membrane. The new approach is evaluated using the "oxygen electrode" as a model system. Results obtained using the new method are compared with results obtained using the conventional steady-state option as well as a coulometric approach described recently. The reproducibility of the pulsed amperometric approach and the scatter of data about least-squares calibration lines are an order of magnitude or more better than for the conventional steady-state option. As expected, the pulsed amperometric method is 40-100-fold less dependent on changes in membrane thickness, stirring rate, and temperature than the conventional steady-state option.
This paper introduces a new approach to the use of membrane-based amperometric sensors which is expected to improve the ruggedness of these sensors significantly relative to the steady-state method in common use. In this new method, the fixed-voltage source used with the conventional steady-state method is replaced by a pulsed-voltage source. Unlike the fixed-source approach, which yields steady-state currents corresponding to large differences between analyte concentrations inside and outside the isolating membrane, the pulsed-source approach permits measurement of currents corresponding to near-equilibrium conditions between solutions inside and outside the membrane. Because the measured currents correspond to near-equilibrium conditions, results are expected to be virtually independent of variables that affect rates of mass transport to and across the membrane. The new approach is evaluated using the "oxygen electrode" as a model system. Results obtained using the new method are compared with results obtained using the conventional steady-state option as well as a coulometric approach described recently. The reproducibility of the pulsed amperometric approach and the scatter of data about least-squares calibration lines are an order of magnitude or more better than for the conventional steady-state option. As expected, the pulsed amperometric method is 40-100-fold less dependent on changes in membrane thickness, stirring rate, and temperature than the conventional steady-state option.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.