Design of a Small-Scale Multi-Inlet Vortex Mixer for Scalable Nanoparticle Production and Application to the Encapsulation of Biologics by Inverse Flash NanoPrecipitation

Abstract: Flash NanoPrecipitation is a scalable approach to generate polymeric nanoparticles using rapid micromixing in specially designed geometries such as a confined impinging jets mixer or a Multi-Inlet Vortex Mixer (MIVM). A major limitation of formulation screening using the MIVM is that a single run requires tens of milligrams of the therapeutic. To overcome this, we have developed a scaled-down version of the MIVM, requiring as little as 0.2 mg of therapeutic, for formulation screening. The redesigned mixer can … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

2
52
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 56 publications
(54 citation statements)
references
References 28 publications
2
52
0
Order By: Relevance
“…Three example formulations using FNP and iFNP are presented below. Two employ the CIJ mixer and one requires the MIVM 15,22 . The first formulation demonstrates encapsulation of a model hydrophobic compound by FNP.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Three example formulations using FNP and iFNP are presented below. Two employ the CIJ mixer and one requires the MIVM 15,22 . The first formulation demonstrates encapsulation of a model hydrophobic compound by FNP.…”
mentioning
confidence: 99%
“…A small-scale version of the MIVM (the μMIVM) with its mixer stand is shown in Figure 2. As with the CIJ, this mixer can be used to encapsulate hydrophobic or hydrophilic compounds 22 . In step 3, a protocol for the encapsulation of a hydrophilic protein, OVA, by iFNP was described.…”
mentioning
confidence: 99%
“…1b) can be used to produce any batch size by scaling production time, nanoparticle processing often involves other unit operations such as tangential flow filtration or spray drying. The mixer size should be matched to the flows and time scales of the other unit operations [9, 24]. Therefore, to avoid operating under conditions where the mixing and assembly regime has changed, a larger MIVM with a higher flow rate may be used.…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, to avoid operating under conditions where the mixing and assembly regime has changed, a larger MIVM with a higher flow rate may be used. We designed the MIVM-5L to operate at a volumetric flow rate of 5 L/min at Re = 10 5 and used a modified form of the design reported by Markwalter and Prud’homme [24]. We adopted a strategy that constrained several parameters within boundaries reported by Liu et al as well as Markwalter and Prud’homme [24, 25].…”
Section: Methodsmentioning
confidence: 99%