Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
A high sensitivity quartz resonant pressure sensor with differential output and self-correction is proposed. Although compared to other resonant devices, quartz resonators have less influence on external environmental factors due to their own high quality factor Q; the influence of external environment such as temperature, vibration, and humidity cannot be ignored in high-precision applications. These errors need to be eliminated or compensated. Therefore, this paper divides the core unit of the sensor into two parts: the working unit and the reference unit. The working unit provides the differential outputs which not only improves the sensitivity but also suppresses some interference such as time drift and temperature drift, and it is rarely used in quartz resonant pressure sensors. The reference unit can effectively detect and offset the interference of temperature and vibration which is named as self-correction, and it can also provide temperature measurement. Double-ended tuning fork quartz resonators used in both units are manufactured by micromachining technology. Bellows and flexible mechanisms used as pressure conversion units are manufactured using modern mechanical technology. The test results show that the sensor has the conformity accuracy of the fitting formula of 0.0148% full scale (FS), the good basic accuracy of 0.06% FS, and the high sensitivity of 36.58 Hz/kPa which meets well with the theoretical result. It is shown by the experiments that the reference unit can effectively correct the interference of temperature and vibration. The theoretical analysis and experimental results prove the feasibility of the resonant pressure sensor which can meet the application requirements of pressure measurement in the high-tech industries.
A high sensitivity quartz resonant pressure sensor with differential output and self-correction is proposed. Although compared to other resonant devices, quartz resonators have less influence on external environmental factors due to their own high quality factor Q; the influence of external environment such as temperature, vibration, and humidity cannot be ignored in high-precision applications. These errors need to be eliminated or compensated. Therefore, this paper divides the core unit of the sensor into two parts: the working unit and the reference unit. The working unit provides the differential outputs which not only improves the sensitivity but also suppresses some interference such as time drift and temperature drift, and it is rarely used in quartz resonant pressure sensors. The reference unit can effectively detect and offset the interference of temperature and vibration which is named as self-correction, and it can also provide temperature measurement. Double-ended tuning fork quartz resonators used in both units are manufactured by micromachining technology. Bellows and flexible mechanisms used as pressure conversion units are manufactured using modern mechanical technology. The test results show that the sensor has the conformity accuracy of the fitting formula of 0.0148% full scale (FS), the good basic accuracy of 0.06% FS, and the high sensitivity of 36.58 Hz/kPa which meets well with the theoretical result. It is shown by the experiments that the reference unit can effectively correct the interference of temperature and vibration. The theoretical analysis and experimental results prove the feasibility of the resonant pressure sensor which can meet the application requirements of pressure measurement in the high-tech industries.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.