2017
DOI: 10.1016/j.apenergy.2016.11.113
|View full text |Cite
|
Sign up to set email alerts
|

Design of closed-loop control system for a bidirectional full bridge DC/DC converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(8 citation statements)
references
References 20 publications
0
7
0
1
Order By: Relevance
“…The conversion of the conventional DC-DC converter into a bidirectional converter can be achieved using a bidirectional switch with a diode, with the current flow in both paths being accepted by anti-parallel with an insulated-gate bipolar transistor (IGBT) or metal-oxide-semiconductor field-effect transistor (MOSFET) employing a controlled switching procedure. Bidirectional DC/DC converters are of two kinds based on existing galvanic isolation between the input and the yield; they are isolated bidirectional DC (IBDC) and non-isolated bidirectional DC (NIBDC) [34,35]. The adaptability of the energy storage system can be improved by using a high-frequency isolated DC-DC converter to replace the line-frequency transformer.…”
Section: Bidirectional Dc-dc Convertersmentioning
confidence: 99%
See 1 more Smart Citation
“…The conversion of the conventional DC-DC converter into a bidirectional converter can be achieved using a bidirectional switch with a diode, with the current flow in both paths being accepted by anti-parallel with an insulated-gate bipolar transistor (IGBT) or metal-oxide-semiconductor field-effect transistor (MOSFET) employing a controlled switching procedure. Bidirectional DC/DC converters are of two kinds based on existing galvanic isolation between the input and the yield; they are isolated bidirectional DC (IBDC) and non-isolated bidirectional DC (NIBDC) [34,35]. The adaptability of the energy storage system can be improved by using a high-frequency isolated DC-DC converter to replace the line-frequency transformer.…”
Section: Bidirectional Dc-dc Convertersmentioning
confidence: 99%
“…With bidirectional DC-DC converters, voltage levels can be either stepped up or down based on the flow control capacity in either direction. According to galvanic isolation, there are two types of bidirectional converter: the first is the isolated bidirectional converter, and the second is the empty of isolation or non-isolated converter [35,[175][176][177].…”
mentioning
confidence: 99%
“…e) Convertidor Puente Completo: Este convertidor opera como un convertidor reductor de voltaje. Es utilizado en aplicaciones de alta potencia, sobre 1kW [18].…”
Section: Convertidores Dc-dcunclassified
“…2(a), the control objective of the offshore collection platform is to maintain the collection system MVdc voltage. Once the HVdc voltage is fixed by the onshore VSC, collection system MVdc voltage can be regulated with closed-loop control as illustrated in [22].…”
Section: B Offshore Collection Platformsmentioning
confidence: 99%