2016
DOI: 10.21595/jve.2016.16812
|View full text |Cite
|
Sign up to set email alerts
|

Design of ELISE robot for the paretic upper limb of stroke survivors

Abstract: To characterize the ELISE project, a concept robot applicable in the neuro-rehabilitation of the entire paretic upper limb. The project has been designed and implemented based on comprehensive rehabilitation of the shoulder, forearm and hand. ELISE is a concept robotic system prepared for individualized approach in rehabilitation of stroke patients including diagnostics, passive and/or active exercises and reports. The ELISE system includes dual biofeedback solutions: rehabilitation exercises in virtual realit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
2

Year Published

2017
2017
2019
2019

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 36 publications
0
7
0
2
Order By: Relevance
“…Onto the inner side, between the top and the bottom part and between the left and the right part of each frame six sets of sensors are placed, which detect the interruptions of the IR light beams (on one side there is a transmitter, and on the other is a receiver). The user performs the exercises by inserting his hand in a frame and thus interrupting a IR beam [21].…”
Section: The Design and The Operational Principle Of The Devicementioning
confidence: 99%
“…Onto the inner side, between the top and the bottom part and between the left and the right part of each frame six sets of sensors are placed, which detect the interruptions of the IR light beams (on one side there is a transmitter, and on the other is a receiver). The user performs the exercises by inserting his hand in a frame and thus interrupting a IR beam [21].…”
Section: The Design and The Operational Principle Of The Devicementioning
confidence: 99%
“…In order to propose a design solution for this type of device, as well as to select appropriate components for the client, it becomes necessary to conduct a detailed analysis of kinematics and dynamics of the manipulator [18].…”
Section: Kinematic and Dynamics Theorymentioning
confidence: 99%
“…• For the component of a hand (with wrist joint), it was used the DS-50-63-310016-13 (rated output torque 18 N·m and acceleration/braking torque 36 N·m) [26].…”
Section: Figurementioning
confidence: 99%
“…The ELISE robot includes a TG Drives digital servo controller with specialized software (TG motion) [26]. Moreover a specialized software application for the control of this multi-module rehabilitation system was created.…”
Section: Figurementioning
confidence: 99%