1984
DOI: 10.1002/cyto.990050616
|View full text |Cite
|
Sign up to set email alerts
|

Design of flow chamber with electronic cell volume capability and light detection optics for multilaser flow cytometry

Abstract: A multibeam optical detection system has been developed with a high optical efficiency, achieved through a reduction in the number of optical interfaces employed in the system. This reduction is made possible by a combination of employing simple lenses, gluing the objective lens directly upon the face of the flow cuvette and the extraction of only one fluorescence signal from each laser beam. A This report describes the design and construction of a flow chamber and associated optical fluorescence detection com… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1987
1987
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…We examined the effect of inhibition of K + channel activity by 4-AP on cell volume (see Figure 5 and Table 2). Cell volume is in direct proportion to the intensity of forward side scatter (FSC), which is used to measure the cell volume [7]. RPMI-8226 cells were cultured in the presence of 2 mM 4-AP for 24 h. The suppression of K + channel activity resulted in 12 ± 3.2%, 19.3 ± 1.6%, and 28 ± 4.3% ( n = 3) increase in cell volume compared with control cells, respectively (Table 1).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…We examined the effect of inhibition of K + channel activity by 4-AP on cell volume (see Figure 5 and Table 2). Cell volume is in direct proportion to the intensity of forward side scatter (FSC), which is used to measure the cell volume [7]. RPMI-8226 cells were cultured in the presence of 2 mM 4-AP for 24 h. The suppression of K + channel activity resulted in 12 ± 3.2%, 19.3 ± 1.6%, and 28 ± 4.3% ( n = 3) increase in cell volume compared with control cells, respectively (Table 1).…”
Section: Resultsmentioning
confidence: 99%
“…Ten thousand events were collected and the data was analyzed with CellQuest software. Forward side scatter (FSC) describing cell size was used to measure the cell volume [7]. …”
Section: Methodsmentioning
confidence: 99%
“…Flow cytometric analysis was performed on PARACYT-I , a custom-built research and development instrument designed in the Laboratory of Parasitic Diseases in collaboration with the Biomedical Engineering and Instrumentation Branch, Division of Research Services of the National Institutes of Health. The instrument utilizes a twosheath flow chamber (42). Two signals/cell, mithramycin-induced fluorescence and forward angle light scatter, were collected.…”
Section: Methodsmentioning
confidence: 99%