2017
DOI: 10.12783/dtetr/icvmee2017/14665
|View full text |Cite
|
Sign up to set email alerts
|

Design of High Precision Ultrasonic Flowmeter Based On TDC-GP22 and Time Difference Method

Abstract: Based on the principle of time difference method and the design concept of high precision, the measuring principle together with the improvement of the calculation method of the time difference method were investigated, aim at the problems of high complexity of the circuit and the inadequate precision of the traditional ultrasonic flowmeter that require pipeline modification. To promote the precision accuracy of the ultrasonic flowmeter to 0.5%, the function principle and its related structure of highprecision… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 0 publications
0
1
0
Order By: Relevance
“…Xia Zhou [7] proposed a dry calibration method for a multi-acoustic path TDOA ultrasonic flowmeter and established a standard experimental platform, which better solved the calibration problem of a large caliber ultrasonic flowmeter. Lv Cheng [8] proposed a flowmeter system design based on ATMEGA single chip and high-precision timing chip TDC-GP22 based on the principle of TDOA and highprecision design concept. Zhang Yao [9] and others proposed a design scheme for the TDOA ultrasonic flowmeter based on the pulse group correlation method in view of the low accuracy and weak antiinterference ability of the TDOA ultrasonic flowmeter in the actual industrial field environment.…”
Section: Introductionmentioning
confidence: 99%
“…Xia Zhou [7] proposed a dry calibration method for a multi-acoustic path TDOA ultrasonic flowmeter and established a standard experimental platform, which better solved the calibration problem of a large caliber ultrasonic flowmeter. Lv Cheng [8] proposed a flowmeter system design based on ATMEGA single chip and high-precision timing chip TDC-GP22 based on the principle of TDOA and highprecision design concept. Zhang Yao [9] and others proposed a design scheme for the TDOA ultrasonic flowmeter based on the pulse group correlation method in view of the low accuracy and weak antiinterference ability of the TDOA ultrasonic flowmeter in the actual industrial field environment.…”
Section: Introductionmentioning
confidence: 99%