2014
DOI: 10.1002/bio.2743
|View full text |Cite
|
Sign up to set email alerts
|

Design of highly sensitive phosphorescence sensor for determination of procaterol hydrochloride based on inhibition of KClO3 oxidation fluorescein isothiocyanate

Abstract: Procaterol hydrochloride (Prh) can inhibit KClO3 oxidation of fluorescein isothiocyanate (FITC) to form a non-phosphorescent compound, which causes room temperature phosphorescence (RTP) of FITC in the system to enhance sharply the linear relationship between ∆Ip and the Prh content. Thus, a rapid response and highly sensitive phosphorescence sensor for the determination of Prh has been developed based on the inhibiting effect of Prh on KClO3 oxidation of FITC. This simple, high sensitivity (detection limit (L… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 22 publications
0
5
0
Order By: Relevance
“…Table displays the average results of seven replicate measurements expressed at a 95% level of confidence obtained for each sample solution using the newly proposed ECL method. The reliability of the proposed technique was evaluated statistically compared with the results of the HPLC method . As shown in Table , the results obtained using the proposed ECL method are consistent with those obtained using HPLC.…”
Section: Resultsmentioning
confidence: 57%
See 3 more Smart Citations
“…Table displays the average results of seven replicate measurements expressed at a 95% level of confidence obtained for each sample solution using the newly proposed ECL method. The reliability of the proposed technique was evaluated statistically compared with the results of the HPLC method . As shown in Table , the results obtained using the proposed ECL method are consistent with those obtained using HPLC.…”
Section: Resultsmentioning
confidence: 57%
“…Table shows the comparison between the analytical performance of the present method and previous literature methods for the determination of ProH. From Table , we found that the proposed ECL method gave a LOD of 0.011 μM, which was better than the LOD of CE‐CD (0.06 μM), CE‐ECL (0.12 μM) and FIA‐CL (0.018 μM) methods, and much higher than that obtained with GC‐ESI‐MS (1.5 × 10 −5 μM) and phosphorescence (1.4 × 10 −5 μM) . However, compared with the GC‐ESI‐MS and phosphorescence methods mentioned above, the new ECL method was much simpler in apparatus and operation.…”
Section: Resultsmentioning
confidence: 77%
See 2 more Smart Citations
“…At present, there are many reports for the determination of biomolecules, such as IgE , myoglobin , dopamine , C‐reactive protein , procaterol hydrochloride , cefditoren pivoxil , nicotinamide by using analytical methods. Quantification of albumin is clinically important, as it has been found to be an effective prognostic indicator.…”
Section: Introductionmentioning
confidence: 99%