2020
DOI: 10.17146/tdm.2020.22.1.5762
|View full text |Cite
|
Sign up to set email alerts
|

Design of Irradiation Facilities at Central Irradiation Position of Plate Type Research Reactor Bandung

Abstract: One of the results from Plate Type Research Reactor Bandung (PTRRB) research program is PTRRB core design. Previous study on PTRRB has not calculated neutron flux distribution at its central irradiation position (CIP). Distribution of neutron flux at CIP is of high importance especially in radioisotope production. In this study, CIP was modeled as a stack of four to five aluminum tubes (AT), each filled by four aluminum irradiation capsules (AIC). Considering AIC dimension and geometry, there are three possibi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…One might draw the conclusion that the gauze bandage turned into a weak radioactive source and that the chamber is sensitive to ionizations caused by the emission of alpha particles from the 222 Rn progeny that has been gathered (Frane & Bitterman, 2022). To conduct the method in various interior locations, the same circumstances may be used (Bahrum et al, 2020). The variance in voltage in each case reveals the variations in the ambient air's concentration of 222 Rn progeny activity in the various rooms (Prayogi, 2022).…”
Section: Resultsmentioning
confidence: 99%
“…One might draw the conclusion that the gauze bandage turned into a weak radioactive source and that the chamber is sensitive to ionizations caused by the emission of alpha particles from the 222 Rn progeny that has been gathered (Frane & Bitterman, 2022). To conduct the method in various interior locations, the same circumstances may be used (Bahrum et al, 2020). The variance in voltage in each case reveals the variations in the ambient air's concentration of 222 Rn progeny activity in the various rooms (Prayogi, 2022).…”
Section: Resultsmentioning
confidence: 99%
“…Although the experiment seems simple, systematic deviations from the exponential law occur during the measurement (Susila et al, 2019). As a result, the measured linear attenuation coefficient deviates significantly from the theoretically predicted value (Bahrum et al, 2020). It appears here that the differences observed are caused by photon stacking (Hamdani et al, 2022), a phenomenon well-known among nuclear engineers and medical physicists, but one that is often overlooked in lecturelaboratory experiments.…”
Section: Introductionmentioning
confidence: 86%