Design of miniaturized nitrite sensors based on silicon structure with back-side contacts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2005
2005
2013
2013

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 36 publications
0
14
0
Order By: Relevance
“…Quite interesting results were reported, for example, for miniaturized ISEs with polymeric membranes containing Co(III)-porphyrin as an ionophore [23]. A hydrogel (pHEMA) layer, containing aqueous internal electrolyte, was used as a intermediate layer in this earlier work, resulting in pronounced improvement of sensor EMF stability with time, compared to sensors with no hydrogel layer.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Quite interesting results were reported, for example, for miniaturized ISEs with polymeric membranes containing Co(III)-porphyrin as an ionophore [23]. A hydrogel (pHEMA) layer, containing aqueous internal electrolyte, was used as a intermediate layer in this earlier work, resulting in pronounced improvement of sensor EMF stability with time, compared to sensors with no hydrogel layer.…”
Section: Resultsmentioning
confidence: 99%
“…Miniaturized planar electrodes with polymeric membranes containing metalloporphyrins were also described, with a hydrogel as an intermediate layer. Co(III)-tetraphenylporphyrin [23], Zr(IV)- tetraphenylporphyrin and Zr(IV)- octaethylporphyrin [24] were used as ionophores for the preparation of electrodes selective towards nitrite and fluoride anion. It was shown that the working parameters (e.g., selectivity, linear range, slopes of the calibration curves) of the sensors were comparable to classic ISEs with bulk internal electrolyte solutions.…”
Section: Introductionmentioning
confidence: 99%
“…In our works BSC silicon-based transducers were also presented [2,5,6]. They were prepared using standard IC technology.…”
Section: Transducers Designmentioning
confidence: 99%
“…Silver was electrochemically deposited from a silver cyanide solution and it was later chlorinized using KCl/HCl solution. For details on the fabrication and the design of transducers see [2,5,6]. The transducers were covered with various chemosensitive materials to obtain sensors of demanded work parameters.…”
Section: Transducers Designmentioning
confidence: 99%
See 1 more Smart Citation