Design of ridge filters for spread-out Bragg peaks with Monte Carlo simulation in carbon ion therapy

Abstract: Spread-out Bragg peaks made by ridge filters or wheel range modulators are used in charged particle therapy with passive methods to achieve uniform biological responses in irradiated tumors. Following the biological responses needed to design the ridge filters, which were developed at the National Institute of Radiological Sciences in Japan, new ridge filters were designed using recent developments in heavy-ion reactions and dosimetry. The Monte Carlo code of Geant4 was used to calculate the qualities of carbo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(34 citation statements)
references
References 34 publications
0
34
0
Order By: Relevance
“…The indifference to the fragments may also be justified by their theoretical difficulty such that even advanced Monte Carlo simulation required empirical correction for them [21]. To select either polyline to apply for a singleL D value, we took the RBE at the proximal end of SOBP, or at d = R − M , as the RBE threshold r BEth per energy per modulation.…”
Section: Formulation Of Rbe-let Relationsmentioning
confidence: 99%
“…The indifference to the fragments may also be justified by their theoretical difficulty such that even advanced Monte Carlo simulation required empirical correction for them [21]. To select either polyline to apply for a singleL D value, we took the RBE at the proximal end of SOBP, or at d = R − M , as the RBE threshold r BEth per energy per modulation.…”
Section: Formulation Of Rbe-let Relationsmentioning
confidence: 99%
“…The ridge filter is a stationary plate shaped device made of aluminum typically (mass density ȡ=2.7 kg/m3), and consists of about a total of 40 ridge bars abreast placed every 5 mm in this modelling. The beam energy will be degraded by bring in the ridge filter [21,22]. After the ridge filter, the Spread-Out Bragg peak will be produced to cover the target in depth with a relatively homogeneous RBE-weighted dose [2][3][4].…”
Section: Description Of the Treatment Head At Impmentioning
confidence: 99%
“…The struggling range of carbon ion beam in MLC saves troubles with the rounded leaf end design caused by photon attenuation in MLC [5]. One of the most important principles of MLC design is to reduce the differences between the dose 50% points and the projected light field edge on axis [6]. The characteristic of the projected light field edge locations and the definition of MLC position as well as the dose 50% points in photon treatment planning system need to be corrected before patients' treatment monitor units are calculated.…”
Section: Introductionmentioning
confidence: 99%