2021
DOI: 10.1080/03772063.2021.1875270
|View full text |Cite
|
Sign up to set email alerts
|

Design, Optimization and Experimental Verification of a Low Cost Two-Microcontroller Based Single-Phase STATCOM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…ZCD circuits are utilized in various applications involving AC source/load for synchronization. In [5], a ZCD circuit is utilized to synchronize the voltage source inverter with the grid in a static synchronous compensator system. In [6][7][8][9][10][11], ZCD circuits are used to control and synchronize various topologies of AC-AC converters.…”
Section: Motivation and Backgroundmentioning
confidence: 99%
See 2 more Smart Citations
“…ZCD circuits are utilized in various applications involving AC source/load for synchronization. In [5], a ZCD circuit is utilized to synchronize the voltage source inverter with the grid in a static synchronous compensator system. In [6][7][8][9][10][11], ZCD circuits are used to control and synchronize various topologies of AC-AC converters.…”
Section: Motivation and Backgroundmentioning
confidence: 99%
“…They also got involved in frequency and phase angle measurement applications in [3,4]. ZCD circuits are usually built using optocouplers [5,11,19], operational amplifiers (op-amps) [19][20][21][22][23], or voltage sensors [6,10,24,25]. Optocoupler-based ZCD circuits provide the required level of isolation, however, they use diodes that lead to delayed ZCD due to the forward voltage drop.…”
Section: Motivation and Backgroundmentioning
confidence: 99%
See 1 more Smart Citation
“…The most important thing in the solar PV integrated grid system is reactive power compensation. The real power only is supplied to the load by using a PV array system, and also excess real power is shared to the grid, and reactive power is not shared by the PV array system [8][9][10][11][12]. If the load requires any reactive power, then the grid has to provide reactive load power.…”
Section: Introductionmentioning
confidence: 99%
“…In [24], the authors have proposed a D-STATCOM based on CSC to enhance the power quality and consistency during step alter in load utilizing PI control. The CHBMC based D-STATCOM using PI control is proposed in [25] to enrich the DC voltage and reactive power control. The control parameters of the PI control are optimized by using the PSO.…”
mentioning
confidence: 99%