2021
DOI: 10.1016/j.enconman.2021.114249
|View full text |Cite
|
Sign up to set email alerts
|

Design optimization of multi-energy systems using mixed-integer linear programming: Which model complexity and level of detail is sufficient?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 56 publications
(18 citation statements)
references
References 57 publications
0
16
0
2
Order By: Relevance
“…Leuthold et al 54 developed a nonlinear mixed-integer programming model to design an electricity market such that public welfare is maximized, with an application to the European electricity market. Wirtz et al 55 proposed a sustainable multicommodity system design model with the power grid attached to the system using mixed integer linear programming. Electric power networks are critical sources of energy that enable the function of other infrastructures, and developing flow balance optimization models for electric power grids has become important for researchers 56 , as have several network flow optimization representations of interdependent infrastructure networks that include electric power 57 60 .…”
Section: Background and Literature Reviewmentioning
confidence: 99%
“…Leuthold et al 54 developed a nonlinear mixed-integer programming model to design an electricity market such that public welfare is maximized, with an application to the European electricity market. Wirtz et al 55 proposed a sustainable multicommodity system design model with the power grid attached to the system using mixed integer linear programming. Electric power networks are critical sources of energy that enable the function of other infrastructures, and developing flow balance optimization models for electric power grids has become important for researchers 56 , as have several network flow optimization representations of interdependent infrastructure networks that include electric power 57 60 .…”
Section: Background and Literature Reviewmentioning
confidence: 99%
“…EC-based CHP can be operated in a flexible way, since steam can usually be extracted from more than one pressure stage, and power may vary with same heat production. In this study, the total energy efficiency of the CHP plant is considered as constant, as suggested in [17,19].…”
Section: Minimum Uptime and Downtimementioning
confidence: 99%
“…The part load efficiency of the gas-fired Heat Only Boiler (HOB) is considered according to the model proposed by [19]. Equation ( 24) provides an expression for the consumption of the HOB boiler, which leads to the non-linear evolution of its efficiency, as shown in Figure 4.…”
Section: Minimum Uptime and Downtimementioning
confidence: 99%
See 1 more Smart Citation
“…Kotzur et al 's two-time layers enable seasonal storage calculation while deploying typical days. In (Beck et al 2022;Göke and Kendziorski 2022;Wirtz et al 2021;Neumann et al 2022;von Wald et al 2022;Hoffmann et al 2020) the storage formulation of Kotzur et al was applied to calculate seasonal storages. Gabrielli et al (2018) developed a different approach to calculate seasonal storage with fewer constraints but more variables.…”
Section: Introductionmentioning
confidence: 99%