“…Both the approaches are computationally costly. Mahendra et al [12] have used an approach which is based on calculation of volume averaged and time averaged dose rate in the post-processing phase. The present approach is computationally much cheaper [12] and agrees well with the experimental dosimetry data [2] as it incorporates features of an Eulerian as well as Lagrangian model by taking dose absorption as well as residence time into account.…”
Section: Dose Parametersmentioning
confidence: 99%
“…Computationally expensive CFD coupled with dose calculation using Monte Carlo photon transport code gave VADR as 0.725 kGy/hr and TADR as 0.664 kGy/hr. The VADR of 0.609 kGy/hr and TADR of 0.812 kGy/ hr [12] was evaluated based on the CFD calculation coupled with Yamakoshi's dose evaluation model [22]. The approach based on recurrent neural network and modified Sievert integral gave VADR as 0.758 kGy/hr and TADR as 0.635 kGy/hr.…”
Section: Validation Of Dose Calculationmentioning
confidence: 99%
“…Subsequent use is made of the product as a safe fertilizer. Mahendra et al [12] carried out design optimization of the irradiator vessel for its multiple planar source assembly. A schematic diagram of an existing irradiator with its source arrangement is shown in Fig.…”
Section: Introductionmentioning
confidence: 99%
“…The irradiator vessel uses set of two Cobalt-60 pencils placed in each of the 13 tubes. All of these 26 numbers of such Cobalt-60 pencils do not have the same radioactivity levels thus optimization is required for source placement in order to maximize the dose absorption [11,12]. Management of sludge flow rate also becomes an important issue so as to maintain the required dose level as the radioactivity decays with time.…”
“…Both the approaches are computationally costly. Mahendra et al [12] have used an approach which is based on calculation of volume averaged and time averaged dose rate in the post-processing phase. The present approach is computationally much cheaper [12] and agrees well with the experimental dosimetry data [2] as it incorporates features of an Eulerian as well as Lagrangian model by taking dose absorption as well as residence time into account.…”
Section: Dose Parametersmentioning
confidence: 99%
“…Computationally expensive CFD coupled with dose calculation using Monte Carlo photon transport code gave VADR as 0.725 kGy/hr and TADR as 0.664 kGy/hr. The VADR of 0.609 kGy/hr and TADR of 0.812 kGy/ hr [12] was evaluated based on the CFD calculation coupled with Yamakoshi's dose evaluation model [22]. The approach based on recurrent neural network and modified Sievert integral gave VADR as 0.758 kGy/hr and TADR as 0.635 kGy/hr.…”
Section: Validation Of Dose Calculationmentioning
confidence: 99%
“…Subsequent use is made of the product as a safe fertilizer. Mahendra et al [12] carried out design optimization of the irradiator vessel for its multiple planar source assembly. A schematic diagram of an existing irradiator with its source arrangement is shown in Fig.…”
Section: Introductionmentioning
confidence: 99%
“…The irradiator vessel uses set of two Cobalt-60 pencils placed in each of the 13 tubes. All of these 26 numbers of such Cobalt-60 pencils do not have the same radioactivity levels thus optimization is required for source placement in order to maximize the dose absorption [11,12]. Management of sludge flow rate also becomes an important issue so as to maintain the required dose level as the radioactivity decays with time.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.