2012
DOI: 10.1016/j.radmeas.2012.06.002
|View full text |Cite
|
Sign up to set email alerts
|

Design parameters and technology optimization of 3He-filled proportional counters for thermal neutron detection and spectrometry applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 23 publications
0
9
0
Order By: Relevance
“…For interactions near the walls there is a probability that one of the products is emitted onto the wall of the detector and its energy is not collected, resulting in the low energy continuum with 2 discontinuities at 191 and 573 keV. Right: pulse-heigh distribution recorded with a 3 He proportional counter, adapted from 5 .…”
Section: Figurementioning
confidence: 99%
See 2 more Smart Citations
“…For interactions near the walls there is a probability that one of the products is emitted onto the wall of the detector and its energy is not collected, resulting in the low energy continuum with 2 discontinuities at 191 and 573 keV. Right: pulse-heigh distribution recorded with a 3 He proportional counter, adapted from 5 .…”
Section: Figurementioning
confidence: 99%
“…In large detectors both products of (1) fully deposit their energy in the proportional gas and the amplitude of the output pulses follows a Gaussian distribution with an average value proportional to Q ( Fig. 1 ) 5 .…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…As such, the typical shape of the pulse height spectrum is independent of the absorbed neutron energy. It is rather a function of the reaction kinematics and detector-specific details, including the geometry (Crane and Baker, 1991 More information about neutron detectors can be found for example in Mazed et al (2012) and Persons and Aloise (2011).…”
Section: Neutron Detectionmentioning
confidence: 99%
“…More broadly, lithium-based scintillators also include lithiated glass [25]- [27] and scintillator crystals [28]- [31]. Other cold/thermal neutron detector technologies are based on helium-3 [32]- [34] or boron-10 [35]- [40], rather than lithium-6 neutron absorber isotope. ZnS(Ag) has a delayed fluorescence response to neutron induced fission of 6 Li, and is much slower for neutrons than for gamma radiation.…”
Section: Introductionmentioning
confidence: 99%