2019
DOI: 10.15587/1729-4061.2019.184400
|View full text |Cite
|
Sign up to set email alerts
|

Designing a single­cascade thermoelectric cooler with the predefined time to enter a stationary mode of operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…where t =10 4 h is the assigned resource. The formula for determining the time of steadystate operation can be presented in the form [19]:…”
Section: Development Of a Thermoelectric Cooler Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…where t =10 4 h is the assigned resource. The formula for determining the time of steadystate operation can be presented in the form [19]:…”
Section: Development Of a Thermoelectric Cooler Modelmentioning
confidence: 99%
“…In [17,18], the results of investigation of the relationship between the dynamics of a thermoelectric cooler and reliability indices at variation of geometry of thermoelements and modes of operation are presented. In [19] the task of reducing the inertia of the cooler and its dependence on the design and loading characteristics is considered. In [20] the possibilities of controlling the operating modes of the cooler by complex indices are presented.…”
Section: Introductionmentioning
confidence: 99%
“…However, these developments were limited to static models and did not take into account dynamics issues relevant for thermal management systems [17,18]. In [19] the results of studies of inertia of a solidstate cooler and connection of reliability indicators with design and energy performance are given. However, control issues related to the use of thermoelectric coolers in the feedback circuit have not been discussed.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The importance of the task of including TEC in the control circuit has led to a series of works related to the study of the relationship of dynamic characteristics and reliability indicators with the design [14], the number of thermocouples [15], current operating modes [16]. In works [17,18] possibilities of optimization of reliability and dynamics indices of fuel injection equipment by complex criteria including these indices are substantiated. At the same time, the conducted researches concern the use of single TEC for thermal mode support systems.…”
Section: Literary Reviewmentioning
confidence: 99%