APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285 1999
DOI: 10.1109/apec.1999.750441
|View full text |Cite
|
Sign up to set email alerts
|

Designing dimmable electronic ballast with frequency control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
6

Year Published

2000
2000
2008
2008

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 51 publications
(13 citation statements)
references
References 13 publications
0
7
0
6
Order By: Relevance
“…In practice, the lamp arc can be considered as a resistor in high frequency operation ( 20 kHz) [8]. The equivalent lamp resistance is defined by , where is the RMS value of the lamp voltage and is the RMS value of the lamp current.…”
Section: A Brief Summary Of Single Sensor Estimation Techniquementioning
confidence: 99%
See 1 more Smart Citation
“…In practice, the lamp arc can be considered as a resistor in high frequency operation ( 20 kHz) [8]. The equivalent lamp resistance is defined by , where is the RMS value of the lamp voltage and is the RMS value of the lamp current.…”
Section: A Brief Summary Of Single Sensor Estimation Techniquementioning
confidence: 99%
“…However, the on-state voltage of these lamps after full ignition is typically less than or around 100 V. The wide range of lamp arc voltage makes it difficult or expensive to install voltage sensor across the lamp directly if the lamp arc condition has to be monitored continuously. For evaluation of various dimming techniques [5], [7], [8], the monitoring of the lamp arc condition and other system parameters is essential. As the lamp arc characteristic is nonlinear and varies with temperature and working life, closed-loop control with lamp power feedback could be a better approach to obtain stable lamp arc operation.…”
Section: Introductionmentioning
confidence: 99%
“…The variable switching frequency control is popularly used in practical implementation because of its simplicity [10][11][12][13][14][15][16][17]. When the switching frequency is located further away from the resonance of the tank, less energy is coupled to the lamps, and the lamps dim.…”
Section: Variable Switching Frequency Controlmentioning
confidence: 99%
“…For the lamp that needs to use a power converter to operate, the control parameter can be classified variable switching frequency control, dynamic duty-ratio control and dynamic bus voltage control. The variable switching frequency control is popularly used in practical implementation because of its simplicity [4][5][6][7][8]. When the switching frequency is located further away from the resonance of the tank, the resonance energy stored in the tank is less and hence less energy is coupled to the lamps, and the lamps dim.…”
Section: Introductionmentioning
confidence: 99%