1988
DOI: 10.1109/28.2886
|View full text |Cite
|
Sign up to set email alerts
|

Destruction of living cells by pulsed high-voltage application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
52
1

Year Published

1997
1997
2017
2017

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 176 publications
(56 citation statements)
references
References 4 publications
3
52
1
Order By: Relevance
“…The most popular theory describing PEF inactivation of microorganisms was recently reviewed by Castro et al (2) and involves pore formation and destruction of the semipermeable membrane barrier. Changes to the S. cerevisiae cells observed by scanning electron microscopy (SEM) after PEF treatment include: surface roughening and pinholes (17), craters or holes (18), elongation, roughening, wrinkling and increased bud scar formation (19). Reports of transmission electron microscopy (TEM) techniques to observe PEF treated yeast cells are not available.…”
Section: Introductionmentioning
confidence: 99%
“…The most popular theory describing PEF inactivation of microorganisms was recently reviewed by Castro et al (2) and involves pore formation and destruction of the semipermeable membrane barrier. Changes to the S. cerevisiae cells observed by scanning electron microscopy (SEM) after PEF treatment include: surface roughening and pinholes (17), craters or holes (18), elongation, roughening, wrinkling and increased bud scar formation (19). Reports of transmission electron microscopy (TEM) techniques to observe PEF treated yeast cells are not available.…”
Section: Introductionmentioning
confidence: 99%
“…Mizuno reported killing living cells using pulsed arc discharges (Mizuno and Hori 1988) and Laroussi (1996) reported the use of DBD to kill bacteria. Kono and Iwamoto (2004) Gliding arc 3 60 Korolev et al (2014), Wu et al (2015) NEAPP -320 Iwasaki et al (2008) LIBS 100 800 Nedanovska et al (2011) In 2006, Fridman reported replacing one of the electrodes in a DBD with a biological object with high capacitance and using it as a floating electrode, as shown in Fig.…”
Section: Plasma Sourcesmentioning
confidence: 99%
“…Researchers have proposed other, more efficient electrode systems for PEF sterilization [22]. Ohshima et al [12] has reported that a partially concentrated PEF yields efficient PEF sterilization.…”
Section: Improvement Of Chamber Structure For Pef Sterilizationmentioning
confidence: 99%