Detecting and quantifying absorbed irrigation fluid by measuring mannitol and sorbitol concentrations in serum samples, and by ethanol monitoring

Abstract: Objective To describe a modi®ed and improved technique which, in one measurement, estimates the in¯ux of irrigation¯uid during endoscopic endometrial ablation or prostate resection, and provides both rapid con®rmation of the diagnosis and an estimate of the amount of¯uid absorbed by detecting markers which pass from the irrigation¯uid to the serum, i.e. mannitol or sorbitol. Patients and methods Control samples were taken for analysis before irrigation, and test samples were taken on four occasions during and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0
2

Year Published

2003
2003
2014
2014

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 27 publications
0
2
0
2
Order By: Relevance
“…Furthermore, in the uterus, a relatively large tissue surface is exposed to diathermy and fluid absorption increases with the extent of the resection as vascular channels on the endometrial surface are opened . A volumetric fluid balance to calculate intravasation during TURP is known to be very inaccurate . In the present study, measurements were hampered by the spill of irrigation fluid and urinary excretion.…”
Section: Discussionmentioning
confidence: 85%
See 1 more Smart Citation
“…Furthermore, in the uterus, a relatively large tissue surface is exposed to diathermy and fluid absorption increases with the extent of the resection as vascular channels on the endometrial surface are opened . A volumetric fluid balance to calculate intravasation during TURP is known to be very inaccurate . In the present study, measurements were hampered by the spill of irrigation fluid and urinary excretion.…”
Section: Discussionmentioning
confidence: 85%
“…The uterus has a relatively thick wall compared with the bladder, requiring high distension pressures. During distension of the uterine cavity, mean intrauterine pressures are up to 100 mmHg .…”
Section: Discussionmentioning
confidence: 99%
“…Aragona 19 estudia la reabsorción de líquido con el método de Etanol en RTU a baja presión. Otros estudios han demostrado la utilidad del etanol como buen marcador de reabsorción [20][21] .…”
unclassified
“…Aragona 19 estudia la reabsorción de líquido con el método de Etanol en RTU a baja presión. Otros estudios han demostrado la utilidad del etanol como buen marcador de reabsorción [20][21] .…”