2015
DOI: 10.1016/j.chemosphere.2015.05.031
|View full text |Cite
|
Sign up to set email alerts
|

Detecting total toxicity in water using a mediated biosensor system with flow injection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 30 publications
1
3
0
Order By: Relevance
“…As a result the greatest response current was observed at high concentration of ferricyanide. On the other hand, at minimum concentration of 0.25 mM of ferricyanide, the smallest response current was detected, indicated that the catalytic response of E.coli depends on the concentration of ferricyanide which was consistent with a previous report [42].…”
Section: Effects Of Mediator Concentration On Ecoli Catalytic Responsesupporting
confidence: 92%
See 1 more Smart Citation
“…As a result the greatest response current was observed at high concentration of ferricyanide. On the other hand, at minimum concentration of 0.25 mM of ferricyanide, the smallest response current was detected, indicated that the catalytic response of E.coli depends on the concentration of ferricyanide which was consistent with a previous report [42].…”
Section: Effects Of Mediator Concentration On Ecoli Catalytic Responsesupporting
confidence: 92%
“…This result indicated that ferricyanide were mediated by the catalytic response of E.coli. The current response was measured at higher (µ A level) even at higher concentration of ferricyanide (45 mM; nA current) reported in other study [42]. This might be due to the high rotation rate of RDE which allows the rapid mass transfer [43] to the electrode surface.…”
Section: Investigation Of Catalytic Response Of Ecolimentioning
confidence: 66%
“…Previous studies have shown that the microbial concentration affects the sensitivity of biotoxicity assessment. 40,41 Fig. S4b † illustrated the influence of microbial concentrations (OD 600 ) on inhibition response caused by Cu 2+ (6 mg L −1 ) on E. coli.…”
Section: Microbial Concentrationmentioning
confidence: 99%
“…In the past decades, many researches of biotoxicity assessment have been mainly focused on the sensitivity and pollutant degradation analysis of aquatic organisms and invertebrates [9][10][11][12], toxicity assessment of bioluminescent bacteria in water and atmospheric particulate matter [13,14] and electrochemical detection of microbial respiratory inhibition [15][16][17]. For example, higher concentration of triclosan has produced great oxidative stress to goldfish under the acidic condition [18].…”
Section: Introductionmentioning
confidence: 99%