2020
DOI: 10.3390/s21010020
|View full text |Cite
|
Sign up to set email alerts
|

Detection and Localization of Partial Discharge in Connectors of Air Power Lines by Means of Ultrasonic Measurements and Artificial Intelligence Models

Abstract: According to the statistics, 40% of unplanned disruptions in electricity distribution grids are caused by failure of equipment in high voltage (HV) transformer substations. These damages in most cases are caused by partial discharge (PD) phenomenon which progressively leads to false operation of equipment. The detection and localization of PD at early stage can significantly reduce repair and maintenance expenses of HV assets. In this paper, a non-invasive PD detection and localization solution has been propos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 33 publications
0
4
0
Order By: Relevance
“…[29] provides an overview of the evolution of smart algorithms for estimating the transformer state. Papers [23,[30][31][32] provide an overview of and consider prospects for the development of real-time RUL estimation techniques. Currently, two basic approaches are used to estimate and forecast the equipment state-based on the health index (HI) and the RUL.…”
Section: The Relevance Of Improving the Rul Forecasting Techniquesmentioning
confidence: 99%
“…[29] provides an overview of the evolution of smart algorithms for estimating the transformer state. Papers [23,[30][31][32] provide an overview of and consider prospects for the development of real-time RUL estimation techniques. Currently, two basic approaches are used to estimate and forecast the equipment state-based on the health index (HI) and the RUL.…”
Section: The Relevance Of Improving the Rul Forecasting Techniquesmentioning
confidence: 99%
“…The best solution is to use ultrasonic discharge counters in association with humidity and temperature sensors. New studies relate to the replacement of O 3 sensors with ultrasonic discharge counter [22]. For example, in [22] the 40 kHz ultrasonic transducer MA40S4R from Murata Manufacturing [23], with 80 • directivity, −63 dB sensitivity and 5 kHz bandwidth at −6 dB level is used for analyzing PD.…”
Section: Ozone Measurements In Pd (Partial Discharge) and Literature ...mentioning
confidence: 99%
“…New studies relate to the replacement of O 3 sensors with ultrasonic discharge counter [22]. For example, in [22] the 40 kHz ultrasonic transducer MA40S4R from Murata Manufacturing [23], with 80 • directivity, −63 dB sensitivity and 5 kHz bandwidth at −6 dB level is used for analyzing PD. Additional machine learning techniques were used to separate the parasitic surrounding noise from the PD signals.…”
Section: Ozone Measurements In Pd (Partial Discharge) and Literature ...mentioning
confidence: 99%
“…Based on dissolved gas analysis (DGA), more scholars adopted the artificial neural network (ANN), the polynomial neural network (PNN), etc., [ 19 , 20 , 21 ]. Moreover, some studies have optimized the algorithms to achieve better results [ 22 , 23 , 24 ]. Compared to the three-ratio method, the adoption of machine learning significantly improved the accuracy of diagnosis.…”
Section: Introductionmentioning
confidence: 99%