2016
DOI: 10.1007/s11239-016-1338-3
|View full text |Cite
|
Sign up to set email alerts
|

Detection and quantification of circulating immature platelets: agreement between flow cytometric and automated detection

Abstract: Immature platelets-also termed reticulated platelets (RP)-are platelets newly released into the circulation, and have been associated with a variety of pathological thrombotic events. They can be assessed by flow cytometry after staining with thiazole orange (TO) or by using a module added to a fully automated analyzer that is currently in wide clinical use and expressed as a fraction of the total platelet count (IPF). We sought to assess the correlation and agreement between these two methods. IPF was measure… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
1

Year Published

2016
2016
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(14 citation statements)
references
References 26 publications
0
13
0
1
Order By: Relevance
“…13 or using automated hematological analyzers, as in the study by Myiazaki 14 and ours. Few studies have formally evaluated the correlation of IPF measurements by these two methods but in two of the most recent ones, this correlation was limited to ITP patients 11, 30 . Considering the challenges of standardizing platelet flow cytometry analyses compared to a CBC, we believe that it is fair to state that the former method should not be regarded as a gold-standard for IPF measurement.…”
Section: Discussionmentioning
confidence: 99%
“…13 or using automated hematological analyzers, as in the study by Myiazaki 14 and ours. Few studies have formally evaluated the correlation of IPF measurements by these two methods but in two of the most recent ones, this correlation was limited to ITP patients 11, 30 . Considering the challenges of standardizing platelet flow cytometry analyses compared to a CBC, we believe that it is fair to state that the former method should not be regarded as a gold-standard for IPF measurement.…”
Section: Discussionmentioning
confidence: 99%
“…First, phosphoACC was determined using immunoblotting in whole platelet lysates. Given the circulating platelets’ heterogeneity (32), it is still unclear whether increased phosphoACC occurs in the entire platelet population or in a subgroup only. Moreover, in this setting, platelets must be purified before phosphoACC is measured, and quantitative assessment of phosphoACC remains challenging.…”
Section: Discussionmentioning
confidence: 99%
“…Although the terms 'reticulated platelets' and 'immature platelets' are used interchangeably, reticulated platelets are detected by flow cytometry with thiazole orange staining of the high RNA content in a reticulated pattern (hence the name 'reticulated platelets') (Kienast & Schmitz 1990), while 'immature' platelets are detected on automated cell counters with an add-on module allowing platelets to be stained with a polyamine/oxazine combination (to detect RNA). Therefore, it should be noted that reticulated platelets and immature platelets do not represent necessarily identical populations even though there is a considerable overlap (Ibrahim et al 2016).…”
Section: Reticulated Platelets and Aspirin Resistancementioning
confidence: 99%