1989
DOI: 10.3109/00313028909059528
|View full text |Cite
|
Sign up to set email alerts
|

Detection and typing of paraproteins: Comparison of different methods in a routine diagnostic laboratory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1995
1995
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…For many years, sIFE has been the gold standard to confirm and characterize the initial detection of an M protein, and, as such, it is used as a comparator for other methods. [44][45][46] Early comparison studies reported a similar sensitivity of ISUB and sIFE for detecting MFLC or small intact M proteins 47,48 (,0.3 g/dL). However, later Jolliff et al 49 reported complete agreement between sIFE and ISUB on 240 cases with M proteins as low as 0.22 g/dL.…”
Section: Guideline Statementsmentioning
confidence: 99%
See 1 more Smart Citation
“…For many years, sIFE has been the gold standard to confirm and characterize the initial detection of an M protein, and, as such, it is used as a comparator for other methods. [44][45][46] Early comparison studies reported a similar sensitivity of ISUB and sIFE for detecting MFLC or small intact M proteins 47,48 (,0.3 g/dL). However, later Jolliff et al 49 reported complete agreement between sIFE and ISUB on 240 cases with M proteins as low as 0.22 g/dL.…”
Section: Guideline Statementsmentioning
confidence: 99%
“…The EP discussed the use of alternative assays that have demonstrated similar sensitivities when compared with sIFE. [44][45][46][47][48][49][50] Again, studies comparing the sensitivity and specificity of sIFE versus other assays, such as ISUB and mass spectrophotometry, were published prior to our inclusion dates. The MASS-FIX technique is relatively new and has shown to have comparable or better sensitivity than sIFE or sFLC.…”
Section: Guideline Statementsmentioning
confidence: 99%
“…The data collected from the scattering of light can be used with computer software to create an electropherogram, which visually represents the various densities as peaks [ 1 ]. Although nephelometry can also be used to quantify immunoglobulins, this assay is not specific for paraproteins and will quantify both the clonal and polyclonal immunoglobulin as a whole [ 49 ].…”
Section: Overview Of Laboratory Techniques Used To Diagnose Igm Pamentioning
confidence: 99%
“…MALT: mucosa-associated lymphoid tissue. References: [ 23 , 24 , 32 , 38 , 40 , 45 , 48 , 49 , 50 ].…”
Section: Figurementioning
confidence: 99%
“…IFE avoids some of the limitations of IEP for identification of IgM (12). Moreover, IFE is more sensitive than IEP (13) for the detection of small monoclonal bands, but the clinical and biological significance of these small bands is unclear (12). Spontaneous disappearance of a measurable M-protein is a rare event (14).…”
Section: Diagnostic and Clinical Aspectsmentioning