2018
DOI: 10.1007/s40291-018-0365-5
|View full text |Cite
|
Sign up to set email alerts
|

Detection of a Traumatic Brain Injury Biomarker at the 10 fg/mL Level

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…Even though other studies report a wider range of detection and lower LODs for S100B [ 40 42 ], this work demonstrates an effective detection of S100B in a clinically relevant range since plasmatic S100B concentrations lower than a cutoff of 100pg/mL [ 9 ] ruled out the presence of bleeding in the CT, while levels below 30pg/mL ruled out BBB disruption [ 10 ]. Furthermore, many of the sensors found in the literature exhibit limitations for a fast analysis due to the requirement of sandwich-type immunoassays and fluorescent labels.…”
Section: Discussionmentioning
confidence: 75%
“…Even though other studies report a wider range of detection and lower LODs for S100B [ 40 42 ], this work demonstrates an effective detection of S100B in a clinically relevant range since plasmatic S100B concentrations lower than a cutoff of 100pg/mL [ 9 ] ruled out the presence of bleeding in the CT, while levels below 30pg/mL ruled out BBB disruption [ 10 ]. Furthermore, many of the sensors found in the literature exhibit limitations for a fast analysis due to the requirement of sandwich-type immunoassays and fluorescent labels.…”
Section: Discussionmentioning
confidence: 75%
“…To achieve voltage-controlled amplification, the WE has been connected to the gating electrode via a DC power supply to apply the gating voltage ( V G ) yielding an electric field at the WE/solution interface and thus resulting in changes of interfacial charge distribution. 130 The proposed technique enabled LDL as low as 10 fg mL −1 in serum which is sufficient for S100β quantification (cutoff for mTBI 42 pg mL −1 , 37 Table 1 ). 130 Importantly, this is one of very few publications on FED-based architectures reporting its successful application in undiluted serum.…”
Section: Types Of Electrochemical (Bio)sensors For Detection Of Protein Biomarkers Relevant To Mtbimentioning
confidence: 97%
“… 130 The proposed technique enabled LDL as low as 10 fg mL −1 in serum which is sufficient for S100β quantification (cutoff for mTBI 42 pg mL −1 , 37 Table 1 ). 130 Importantly, this is one of very few publications on FED-based architectures reporting its successful application in undiluted serum.…”
Section: Types Of Electrochemical (Bio)sensors For Detection Of Protein Biomarkers Relevant To Mtbimentioning
confidence: 97%
See 2 more Smart Citations