2007
DOI: 10.1007/s00264-007-0404-z
|View full text |Cite
|
Sign up to set email alerts
|

Detection of bone and cartilage-related proteins in plasma of patients with a bone fracture using liquid chromatography–mass spectrometry

Abstract: Following bone fracture, a large number of growth factors, cytokines, and their cognate receptors involved in the repair process are active at the fracture site. To determine whether they appear in patients' blood as candidate biomarkers for following the outcome of healing, we analysed the plasma of 25 patients with an acute bone fracture following affinity plasma purification, SDS gel electrophoresis and liquid chromatography -tandem mass spectrometry (LC-MS/ MS). Two hundred and thirteen nonredundant protei… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
5
3
1

Relationship

5
4

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 16 publications
0
19
0
Order By: Relevance
“…Recently, using LC‐MS PCPE1 was found in the plasma of patients with acute bone fractures (Grgurevic et al. ), and PCPE1 has been proposed as a biomarker to follow collagen type I metabolism (Mesilaty‐Gross et al. ).…”
Section: Discussionmentioning
confidence: 99%
“…Recently, using LC‐MS PCPE1 was found in the plasma of patients with acute bone fractures (Grgurevic et al. ), and PCPE1 has been proposed as a biomarker to follow collagen type I metabolism (Mesilaty‐Gross et al. ).…”
Section: Discussionmentioning
confidence: 99%
“…Easy-nLC nanoflow HPLC system (Proxeon Biosystems) was coupled to a LTQ-Orbitrap mass spectrometer (Thermo Scientific) using a nanoelectrospray LC-MS interface (Proxeon Biosystems). Peptides were loaded on a home-made 75 µm C18 HPLC column in solvent "A" (0.5% acetic acid in Milli-Q water) and eluted with a 70-minute segmented linear gradient of 10-60% solvent "B" (80% acetonitrile, 0.5% acetic acid in Milli-Q water) at a flow rate of 250 nL/min as described [30].…”
Section: Mass Spectrometrymentioning
confidence: 99%
“…Plasma was purified by heparin affinity chromatography as described. 50 Bound proteins were eluted and precipitated with saturated ammonium sulfate to a final concentration of 35%. The samples were kept on ice for 10 minutes and centrifuged for 5 minutes at 12,000 ϫ g. The supernatant was discarded and the pellet was subjected to SDS-PAGE and Western blot analysis as described.…”
Section: Plasma Collection and Purificationmentioning
confidence: 99%