2020
DOI: 10.2214/ajr.19.21881
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Bone Marrow Edema in the Head and Neck With Dual-Energy CT: Ready for Clinical Use?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…Numerous applications of DECT have been described in head and neck imaging. 10,[13][14][15][16][17][18][19][20][21] Previously published studies of dual-energy parathyroid CT have primarily focused on the potential for radiation dose reduction using virtual noncontrast images to eliminate the standard noncontrast phase 22,23 and on describing quantitative dual-energy characteristics of parathyroid adenomas, thyroid parenchyma, and lymph nodes on postcontrast phases. 24,25 The authors are aware of 1 previous study that evaluated dual-energy noncontrast parathyroid CT images obtained on a dual-source system using 90-keV, 150-keV, and mixed images (dual-energy composition factor, 0.8), but 40-keV VMI were not specifically evaluated in this previous investigation.…”
Section: Discussionmentioning
confidence: 99%
“…Numerous applications of DECT have been described in head and neck imaging. 10,[13][14][15][16][17][18][19][20][21] Previously published studies of dual-energy parathyroid CT have primarily focused on the potential for radiation dose reduction using virtual noncontrast images to eliminate the standard noncontrast phase 22,23 and on describing quantitative dual-energy characteristics of parathyroid adenomas, thyroid parenchyma, and lymph nodes on postcontrast phases. 24,25 The authors are aware of 1 previous study that evaluated dual-energy noncontrast parathyroid CT images obtained on a dual-source system using 90-keV, 150-keV, and mixed images (dual-energy composition factor, 0.8), but 40-keV VMI were not specifically evaluated in this previous investigation.…”
Section: Discussionmentioning
confidence: 99%
“…BME is a prodrome of bone destruction and a prediction marker for worsening of symptoms 9,10 . It is also one of the first signs of inexplicable pain or teeth mobility 28 . Recently, DECT has not become available in clinical practice to detect BME caused by various diseases [1][2][3][4][5] .…”
Section: Discussionmentioning
confidence: 99%
“…It is being used to visualize subtle bone involvement in oncology, osteomyelitis, and osteonecrosis of the head and neck region 8 . The sensitivity and specificity of DECT for the detection of BME with VNCa DECT reconstructions were investigated in numerous studies and were found to be relatively high at 82-96% and 83-98%, respectively [28][29][30] . Therefore, DECT is a reliable diagnostic tool for the detection of BME.…”
Section: Discussionmentioning
confidence: 99%
“…Recent data from studies with new-generation dual-energy CT systems suggest an improved detection of tumour invasion into cartilage, cortical bone, and bone marrow [ 64 , 65 ].…”
Section: Quantitative Diagnosismentioning