2013
DOI: 10.1016/j.chroma.2013.09.042
|View full text |Cite
|
Sign up to set email alerts
|

Detection of C-reactive protein based on magnetic nanoparticles and capillary zone electrophoresis with laser-induced fluorescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 20 publications
0
7
0
Order By: Relevance
“…An immunoassay based on the use of magnetic nanobeads was used for efficient sample pretreatment to determine haptoglobin, a biomarker for Alzheimer's disease [200], and c‐reactive protein (CRP), a biomarker for acute and chronic inflammation [201] in human plasma by CZE with laser‐induced fluorescence detection. Haptoglobin and CRP were immobilized on the magnetic nanobeads and reacted with the purified anti‐haptoglobin/CRP antibody, and the labeled secondary antibodies reacted with the complex.…”
Section: Immunoaffinity Methodsmentioning
confidence: 99%
“…An immunoassay based on the use of magnetic nanobeads was used for efficient sample pretreatment to determine haptoglobin, a biomarker for Alzheimer's disease [200], and c‐reactive protein (CRP), a biomarker for acute and chronic inflammation [201] in human plasma by CZE with laser‐induced fluorescence detection. Haptoglobin and CRP were immobilized on the magnetic nanobeads and reacted with the purified anti‐haptoglobin/CRP antibody, and the labeled secondary antibodies reacted with the complex.…”
Section: Immunoaffinity Methodsmentioning
confidence: 99%
“…However, this treatment usually infers further analytical use of the conjugate. For magnetic nanoparticles magnetic separation is the possible method of choice . The type of interaction (electrostatic, covalent coating, etc.)…”
Section: Ce Methodology In Nano–bio Researchmentioning
confidence: 99%
“…Depending on their fluorescent properties, they can be detected either directly (e.g. down to 2 × 10 −10 M for γ‐Fe 2 O 3 ‐silica core‐shell nanoparticles functionalized with PEG ) or after surface modification by the attachment of a fluorescence probe . Additionally, fluorescence measurements based on use of inverted fluorescence microscope have been applied to monitor the self‐assembling of QDs with various biomolecules inside the capillary and also with QDs added to BGE (as a probe), to determine various biomolecules [; see also a commentary on this topic by Vaculovicova et al.…”
Section: Ce Methodology In Nano–bio Researchmentioning
confidence: 99%
“…Lin et al used protein G modified MNP in CE with LIF detection to analyze C-reactive protein (CRP), which is a wellknown biomarker of acute and chronic inflammatory. The protein G modified MNP that was formed covalently binds to anti-CRP antibody 1, CRP, and FITC labeled anti-CRP antibody 2, and CRP was directly analyzed by CE with LIF detection, without elution of CRP from the MNP surface [66], as shown in Fig. 4.…”
Section: Application Of Nanoparticles In Cementioning
confidence: 99%