Detection of cardiovascular disease associated miR-29a using paper-based microfluidics and surface enhanced Raman scattering

Abstract: A paper-based microfluidics self-testing device capable of colorimetric and SERS-based sensing of cardiovascular disease associated miR-29a has been developed for improving patient care and triage.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 50 publications
(32 citation statements)
references
References 43 publications
0
32
0
Order By: Relevance
“…To avoid any Raman signal background for the test lines, the LF strips were then washed by dipping into 0.01 M Tris buffer (pH 8.4) for 5 minutes, then allowed to dry at room temperature. Strips were then fixed onto an in-house 3D printed Raman aperture adaptor that was used as a sample holder 35 and the test lines were scanned using a handheld Raman spectrometer (CBEx, Snowy Range Instruments, USA). All the SERS measurements were carried out using orbital raster scanning (ORS) mode over the range 600-1800 cm -1 using the Peak 1.3.68 software.…”
Section: Sers Calibration Curves For Slpa and Toxbmentioning
confidence: 99%
“…To avoid any Raman signal background for the test lines, the LF strips were then washed by dipping into 0.01 M Tris buffer (pH 8.4) for 5 minutes, then allowed to dry at room temperature. Strips were then fixed onto an in-house 3D printed Raman aperture adaptor that was used as a sample holder 35 and the test lines were scanned using a handheld Raman spectrometer (CBEx, Snowy Range Instruments, USA). All the SERS measurements were carried out using orbital raster scanning (ORS) mode over the range 600-1800 cm -1 using the Peak 1.3.68 software.…”
Section: Sers Calibration Curves For Slpa and Toxbmentioning
confidence: 99%
“…DEP force was employed to improve the performance of mixing and preconcentration. In another case, paper-based microfluidic SERS system was applied for point-of-care test of microRNA [120]. Driven by capillary action, this system can realize multistep SERS-active nanoparticle conjugation, target microRNA capture, washing, and SERS detection automatically.…”
Section: Multistep Biomacromolecule and Cell Surface-enhanced Raman Spectroscopy Analysismentioning
confidence: 99%
“…For that reason, researchers have utilized and combined different methods to increase sensitivity, accuracy, and reproducibility of the results. To make POCT and on-field monitoring more affordable, interestingly, supporting devices gradually have been scaled down to minimal but still in well-functioned forms such as printed heater [ 182 ], portable fluorometer [ 195 ], mobile power supply [ 196 ], handheld Raman spectrometer [ 197 ], etc. This is indeed a very dramatic transformation that triggers the competition between manufacturers and allows small enterprises to enter the market, thus opening up the opportunity of commercialization of µPADs.…”
Section: Conclusion and Future Perspectivesmentioning
confidence: 99%