2003
DOI: 10.1117/12.477975
|View full text |Cite
|
Sign up to set email alerts
|

Detection of glaucomatous retinal nerve fiber layer damage by scanning laser polarimetry with custom corneal compensation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
41
0

Year Published

2004
2004
2016
2016

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(42 citation statements)
references
References 0 publications
1
41
0
Order By: Relevance
“…Note that the data were calculated from the thickness map, provided by the GDx, assuming a constant conversion factor of 0.67 nm/lm and an imaging wavelength of 785 nm. 5 It is worth noting here that the retardation values measured by the GDx-VCC were recorded at an imaging wavelength of 785 nm and that the PS-OCT retardation values were recorded at 840 nm. To compare the values correctly (retardation in degrees) provided by both systems, the GDx-VCC results were multiplied by a factor of 785/840.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Note that the data were calculated from the thickness map, provided by the GDx, assuming a constant conversion factor of 0.67 nm/lm and an imaging wavelength of 785 nm. 5 It is worth noting here that the retardation values measured by the GDx-VCC were recorded at an imaging wavelength of 785 nm and that the PS-OCT retardation values were recorded at 840 nm. To compare the values correctly (retardation in degrees) provided by both systems, the GDx-VCC results were multiplied by a factor of 785/840.…”
Section: Resultsmentioning
confidence: 99%
“…9,31 The next post-processing step was to correct the polarization sensitive data for an influence of the birefringence of the anterior segment. While the GDx-VCC measures the anterior segment birefringence in the macula and adjusts a variable wave plate for correction, 5 we obtained the anterior birefringence data from a measurement of the polarization state at the retinal surface and used a software-based correction approach. 32 In a next step, we used the 3D polarization sensitive data to generate 2D en face maps of the RNFL retardation.…”
Section: Ps-oct Data Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Additional knowledge about light polarizing properties of tissues in health and disease can be obtained from preclinical research involving animals. Important information such as the conversion factor from birefringence to RNFL thickness via birefringence measurements in scanning laser polarimetry was obtained from animals and then translated to human imaging [58,59]. In a recent study, we used a PS-OCT system with lower resolution of 7.6 µm in air (5.6 µm in tissue) to study birefringence in the peripapillary rat sclera in vivo [33].…”
Section: Discussionmentioning
confidence: 99%
“…Methods for AS compensation used in the past have included external polarization elements to "neutralize" the ASR so that it does not appear in the dataset (GDx [169] and GDx-VCC [195]), and mathematical methods to extract the ASR from the dataset after it has been collected (GDx-ECC [181]). Given that ASR is by design incorporated into GDx-MM data, and given that a direct measurement of ASR (for example by viewing the fourth Purkinje image) is not possible here, it is necessary to estimate the ASR and then extract it as a post-processing step.…”
Section: Set 5: Spectralonmentioning
confidence: 99%