2011
DOI: 10.1016/j.joen.2011.05.040
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Horizontal Root Fracture with Small-volume Cone-Beam Computed Tomography in the Presence and Absence of Intracanal Metallic Post

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

9
89
1
18

Year Published

2012
2012
2022
2022

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 79 publications
(117 citation statements)
references
References 25 publications
9
89
1
18
Order By: Relevance
“…Several studies have confirmed the superiority of CBCT over periapical radiographs for detection of root and endodontic conditions, 6,7,14,15,22 but other studies demonstrated that gutta-percha and metal posts produce artefacts that make visualization of fracture lines in endodontically treated and restored teeth a challenging task. 4,6,7,9,14,16 The beamhardening effect, for instance, causes the edges of metallic objects to appear brighter than their centres and produces hyperdense streak-like artefacts that can impair diagnostic performance. 6,7,9,15,16 We tested whether CBCT filters could be an option to decrease the influence of the artefacts on the diagnosis of VRF.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Several studies have confirmed the superiority of CBCT over periapical radiographs for detection of root and endodontic conditions, 6,7,14,15,22 but other studies demonstrated that gutta-percha and metal posts produce artefacts that make visualization of fracture lines in endodontically treated and restored teeth a challenging task. 4,6,7,9,14,16 The beamhardening effect, for instance, causes the edges of metallic objects to appear brighter than their centres and produces hyperdense streak-like artefacts that can impair diagnostic performance. 6,7,9,15,16 We tested whether CBCT filters could be an option to decrease the influence of the artefacts on the diagnosis of VRF.…”
Section: Discussionmentioning
confidence: 99%
“…4,6,7,9,14,16 The beamhardening effect, for instance, causes the edges of metallic objects to appear brighter than their centres and produces hyperdense streak-like artefacts that can impair diagnostic performance. 6,7,9,15,16 We tested whether CBCT filters could be an option to decrease the influence of the artefacts on the diagnosis of VRF. It appears that the application of enhancement filters in digital radiography makes diagnosis of 23,25 As one may conclude, the influence of filters on aiding dental diagnosis is still controversial; furthermore, most studies about the diagnostic advantages of filters used periapical radiographs, and the few studies that evaluated the application of CBCT filters for diagnosis of root fractures did not include teeth with intracanal materials.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…According to Yamauchi et al 15 and Costa et al 20 and also Cavalcanti,21 OsiriX is easy-to-use open source software, offering advanced and useful postprocessing imaging protocols, thus making it a versatile DICOM viewer offering regular updates. In our opinion the post-processing method used in this software is a new and important tool for the den- 21 our study demonstrated the assessment of MF and AMF for implant planning.…”
Section: Discussionmentioning
confidence: 99%
“…24 Parirokh ve arkadaşları 25 tarafından bildirilen olgu sunumunda; KIBT görüntülerinde kök etrafında radyolüsent lezyon saptanan metal kanal postlu dişin, konvansiyonel radyografik inceleme ve dental operatif mikroskop ile incelemesi sonucu herhangi bir patolojiye sahip olmadığı belirtilmiştir. KIBT'da saptanan bu radyolüsent görüntünün, metal kanal postundan kaynaklanan artefakt olduğu ve yanlış teşhise yol açtığı bildirilmiştir.…”
Section: Edi̇nme (Acquisition) Artefaktlariunclassified