Biomedical Applications of Micro- And Nanoengineering III 2006
DOI: 10.1117/12.695682
|View full text |Cite
|
Sign up to set email alerts
|

Detection of inorganic ions on a capillary electrophoresis microchip using a conductivity technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2008
2008
2016
2016

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…Figure 3 shows the simplest design which has two metal electrodes placed onto capping layer of PC microchip 10,11 . After an AC signal (316kHz, 8V) is applied to the drive electrode, current passes the capping layer, the detection gap between the electrodes, and back to the pick-up electrode.…”
Section: Contactless Conductivity Detector (Ccd)mentioning
confidence: 99%
“…Figure 3 shows the simplest design which has two metal electrodes placed onto capping layer of PC microchip 10,11 . After an AC signal (316kHz, 8V) is applied to the drive electrode, current passes the capping layer, the detection gap between the electrodes, and back to the pick-up electrode.…”
Section: Contactless Conductivity Detector (Ccd)mentioning
confidence: 99%
“…A simple two electrode design of the CCD sensor array was used for this work [19]. The conductivity detector electronic circuit was implemented according to the design of Da Silva et al [20].…”
Section: Contactless Conductivity Detection (Ccd)mentioning
confidence: 99%
“…CCD detectors continue to be the preferred choice due to their low cost, simplicity to handle and flexible measurement scheme 18. The detector electrodes could be attached on the chip bottom surface 129, assembled on an independent (and replaceable) plate 130 or similarly as a part of the chip holder 131, screen‐printed or thin‐film configured 132. Sensitivity of CCD can be substantially improved by reducing the electrode impedance, e.g .…”
Section: Microchip Electrophoresis: On the Way To Routine Usementioning
confidence: 99%
“…The favored materials for microchip fabrication (including commercially available chips) encompass various polymers, e.g . PMMA 131, 132, 140, polycarbonate 106, 129, PDMS 135–138 or glass 130, 134, 137, 139, 141. There is a certain indication that PDMS substrate material may take a dominating place in prototyping microchip analytical devices, at least at a research stage.…”
Section: Microchip Electrophoresis: On the Way To Routine Usementioning
confidence: 99%