1994
DOI: 10.1016/s0002-9394(14)73077-6
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Intraocular Antibody Production to Herpesviruses in Acute Retinal Necrosis Syndrome

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
37
0
6

Year Published

1995
1995
2022
2022

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 97 publications
(47 citation statements)
references
References 28 publications
0
37
0
6
Order By: Relevance
“…Es traten lediglich bei 5 Augen "Rezi-nen stellen jedoch lediglich Epiphänomene ohne pathogenetisch wirksame Effektivität dar (Kalden 1994 Die intraokulare Antikörperproduktion wird von manchen Autoren als Beweis für eine intraokulare Infektion angesehen (Remky 1961, Witmer 1962, Desmonts 1973, Witmer 1978, Hartmann et al 1991, Baarsma et al 1991, De Boer et al 1994, Abe et al 1996, Remky 1998, Lightman und Towler 1998, andere fordern den Erregernachweis in den erkrankten Augen (Bryans 1955, Schebitz und Dedié 1955, Thiermann 1984, Kalsow und Dwyer 1997.…”
Section: Rezidivfreiheit Nach Vitrektomieunclassified
“…Es traten lediglich bei 5 Augen "Rezi-nen stellen jedoch lediglich Epiphänomene ohne pathogenetisch wirksame Effektivität dar (Kalden 1994 Die intraokulare Antikörperproduktion wird von manchen Autoren als Beweis für eine intraokulare Infektion angesehen (Remky 1961, Witmer 1962, Desmonts 1973, Witmer 1978, Hartmann et al 1991, Baarsma et al 1991, De Boer et al 1994, Abe et al 1996, Remky 1998, Lightman und Towler 1998, andere fordern den Erregernachweis in den erkrankten Augen (Bryans 1955, Schebitz und Dedié 1955, Thiermann 1984, Kalsow und Dwyer 1997.…”
Section: Rezidivfreiheit Nach Vitrektomieunclassified
“…3,17 The GWC was considered positive when its value exceeded 3. 11,18 None of the samples was inhibited during PCR analysis or were unable to be analyzed for the presence of antibody. Of the 56 samples, 27 were analyzed at the NORI and 29 at the UMCU.…”
mentioning
confidence: 99%
“…For this reason, cultures of samples from the virtually cell-free aqueous and vitreous compartments are negative; therefore, such means cannot be used to establish viral etiology [9,11,12]. However, analysis of paired aqueous and serum samples for the existence of specific antibodies has led to successful diagnoses in 65% of cases [13][14][15]; if this procedure is carried out on a sequential basis, 72%-86% of cases may be successfully diagnosed [16].…”
mentioning
confidence: 99%