2023
DOI: 10.1117/1.jbo.28.12.121204
|View full text |Cite
|
Sign up to set email alerts
|

Detection of low-frequency oscillations in neonatal piglets with speckle contrast diffuse correlation tomography

Abstract: Significance: Low-frequency oscillations (LFOs) (<0.1 Hz) with respect to cerebral blood flow (CBF) have shown promise as an indicator of altered neurologic activity in the abnormal brain. Portable optical instruments have evolved to offer a noninvasive alternative for continuous CBF monitoring at the bedside compared with many large neuroimaging modalities. However, their utilization for acquiring LFOs of CBF has only been studied to a limited extent.Aim: We aim to optimize an innovative speckle contrast diff… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(6 citation statements)
references
References 76 publications
0
6
0
Order By: Relevance
“…A highperformance long-pass filter (>750 nm; #84-761, EdmundOptics) was used to minimize the influence of ambient light on DSCT measurements. 26 No obvious influence of ambient light was observed on the obtained raw intensity images or reconstructed BFI maps from the experiments. A pair of polarizers (LPNIRE050-B and LPNIRE200-B, Thorlabs) crossing the source and detection paths were added to reduce the specular reflection directly from the scanning light sources on the tissue surface.…”
Section: Hybrid Dsct and Lsci Systemmentioning
confidence: 83%
See 4 more Smart Citations
“…A highperformance long-pass filter (>750 nm; #84-761, EdmundOptics) was used to minimize the influence of ambient light on DSCT measurements. 26 No obvious influence of ambient light was observed on the obtained raw intensity images or reconstructed BFI maps from the experiments. A pair of polarizers (LPNIRE050-B and LPNIRE200-B, Thorlabs) crossing the source and detection paths were added to reduce the specular reflection directly from the scanning light sources on the tissue surface.…”
Section: Hybrid Dsct and Lsci Systemmentioning
confidence: 83%
“…Following our established method, 20,26 raw intensity images were prescreened to ensure that the detected light intensities (counts) were within the linear range of our camera and above the minimal SNR requirement (i.e., SNR > 3). The DSCT method first converted each of the raw intensity images taken at different source locations within the ROI into a speckle contrast image based on the fast LSCI analysis utilizing the Image Processing Toolbox™ and Parallel Computing Toolbox™ (Sec.…”
Section: Dsct Methods For 2d Mapping Of Cbf At Different Depthsmentioning
confidence: 99%
See 3 more Smart Citations