2015
DOI: 10.1016/j.bios.2015.03.041
|View full text |Cite
|
Sign up to set email alerts
|

Detection of methicillin-resistant staphylococci by biosensor assay consisting of nanoscale films on optical fiber long-period gratings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
31
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 49 publications
(33 citation statements)
references
References 47 publications
2
31
0
Order By: Relevance
“…What is more, the sensitivity and sensitive range of this LPFG sensor to RI can continue to be improved and adjusted by coating nanofilm on the surface of the LPFG [10,15,23,24,25,26]. The kinds of LPFGs with a period of 180 µm and red-shifted resonant peaks are extremely conducive to applications in physical, biological, and chemical sensing due to their overwhelmingly high RI sensitivity.…”
Section: Resultsmentioning
confidence: 99%
“…What is more, the sensitivity and sensitive range of this LPFG sensor to RI can continue to be improved and adjusted by coating nanofilm on the surface of the LPFG [10,15,23,24,25,26]. The kinds of LPFGs with a period of 180 µm and red-shifted resonant peaks are extremely conducive to applications in physical, biological, and chemical sensing due to their overwhelmingly high RI sensitivity.…”
Section: Resultsmentioning
confidence: 99%
“…Technical details of fabrication of the ISAM films and the NOFS operation have been described. 3,34 The ISAM method involves the alternate dipping of a charged substrate (optical fiber) into an aqueous solution of a polycation and then an aqueous solution of a polyanion at room temperature ( Supplementary Fig. 1).…”
Section: Fabrication Of the Isam Filmmentioning
confidence: 99%
“…; Bandara et al . ), the distinction between MSSA and MRSA strains thanks to an IgG recognizing PBP2a is presented. The authors used respectively SPR and optical fibre‐based read‐out as transducing techniques.…”
Section: Whole‐cell Detection With Biosensors Dedicated To S Aureusmentioning
confidence: 99%
“…Besides, there is no control experiment with a nonspecific antibody which would assess the importance of protein A interactions with the Fc region. Similarly, in two papers (Tawil et al 2013;Bandara et al 2015), the distinction between MSSA and MRSA strains thanks to an IgG recognizing PBP2a is presented. The authors used respectively SPR and optical fibre-based read-out as transducing techniques.…”
Section: Immunoglobulinsmentioning
confidence: 99%